SD-19045-003 MOLEX

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(free datasheet download site)
  • PDF pages: 5

Technical content

REVISION: ECR/ECN INFORMATION: TITLE: SELF CONTAINED POWER CONNECTOR (COC-1) INSTALLATION INSTRUCTIONS FOR 2 WIRE CABLE WITH GROUND APPLICATIONS SHEET No. EC No: 624224 1 of 3 DATE: 2019 / 09 / 19 DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY: SD-19045-003 ETHRODAHL/ DMYRICK JMACNEIL JMACNEIL TEMPLATE FILENAME: ENGINEERING_SPECSIZE_A.DOC INSTALLATION INSTRUCTION SHEETS

1.0 SCOPE

This specification consists of installation instructions for the Self-Contained Power Connector for 2-wire solid cable with ground applications.

2.0 PURPOSE

To define material number system for the above instructions.

3.0 REFERENCE MATERIAL NUMBERS

See pages 2-3 for the actual instruction sheets. These pages can be used as originals.

4.0 DEFINITIONS

Not applicable.

5.0 PROCEDURES

Place one (1) instruction sheet in the smallest unit container.

6.0 IMPLEMENTATION

JANUARY 31, 2009

FIG. 2 COC-1 Self-Contained Power Connector Installation Instructions For 2 Wire Cable with Ground Applications The 2-circuit-with-ground connectors will splice non-metallic-sheathed cable in th e following wire ranges and types: Reference Information UL File Number: E182087, CSA File Number: LR18689-C53 NEC Article: 550, 551, and 545 HUD Section: 3280.801 Current: 20A,Voltage: 300V Installation Procedure: 1. Carefully strip and prepare the wires to the configuration as shown in Figure 1 using helpful hints shown in photographs of Figure 2. 2. Hold the clear strain relief cover with bottom facing upward as shown in Figure 3. 3. Lay wire into locator slots, making sure the black wire is placed into the polarization slot as shown in Figure 3. 4. Press the cable sheath into the integral strain relief slot as shown in Figure 3. Trimming of ground wire and possibly others will be necessary. Wires must not extend beyond the locators as shown in Figure 4! 5. While holding the strain relief cover, position the housing’s hinge posts into the hinge slots and press down until both lock into place as shown in Figure 4. 6. Close the strain relief cover and housing by hand. Place the connector assembly into Molex tool (preferred) as shown in Figure 5. Squeeze the tool until the connector bottoms out and the locking latches engage on both sides. OR alternately, squeeze the top and bottom closed with tongue and groove pliers as shown in Figure 5.1. Pliers must be a minimum of 10" long. Squeeze firmly on both sides, squarely across the connector between ribs A and B to ensure wires seat completely into slots. 7. Inspect the connector to ensure the wires have been properly engaged into the housing assembly contacts. A properly terminated wire is fully seated into its proper slots with no significant bow of the cover. If the wires extend past the insulation stops, the wires must be re-terminated with a NEW CONNECTOR. Once the cover has been closed the connector cannot be re-used. Failure to comply with this procedure may result in the failure of the connector. 8. Mating and un-mating the completed connector is illustrated in Figure 6. Self-Contained Connector -

2 Circuit with ground for Solid Wire

Wire Range Order Optional Optional Bench Optional Bench Housing AWG No. Hand Tool Mount Tool Arbor Press Color 12-14 19045-1000 19285-0074 N/A 64006-0200 White (COC-1)