1829A BELDEN
Document overview
- Manufacturer or author: Provided By www.digicamel.com(free datasheet download site)
- PDF pages: 3
Technical content
Product: 1829A Broadband Coax, Series 6, 18 AWG Solid BCCS, Foil + 60% AL Braid, PVC Jkt, CM Product Description Broadband Coax, Series 6, 18 AWG Solid Bare Copper Covered Steel Conductor, PE Insulation, Foil + 60% Aluminum Braid Shield, PVC Jacket, CM Technical Specifications Product Overview Suitable Applications: Broadband, Cable Television (CATV), RF drop cable, Direct Broadcast Satellite (DBS), Over-The-Air (OTA) antennas Construction Details Series Type: 6 Conductor Size Stranding Nom. Diameter Material 18 AWG Solid 0.040 in BCCS - Bare Copper Covered Steel Insulation Material Nom. Insulation Diameter Color Code PE - Polyethylene (Foam) 0.180 in (4.57 mm) White Outer Shield Layer Outer Shield Type Material Material Trade Name Coverage
1 Tape Tri-Laminate (Alum+Poly+Alum) Duobond® II 100%
2 Braid Aluminum 60%
Material Nom. Diameter PVC - Polyvinyl Chloride 0.270 in (6.86 mm) Overall Cable Diameter (Nominal): 0.270 in (6.86 mm)
Electrical Characteristics
Return Loss (RL) Frequency Min. Structural Return Loss 950 - 2250 MHz 15 dB 2250 - 3000 MHz 10 dB Attenuation Frequency Max. Attenuation 5 MHz 0.58 dB/100ft 55 MHz 1.60 dB/100ft 211 MHz 3.05 dB/100ft 250 MHz 3.30 dB/100ft 270 MHz 3.37 dB/100ft 300 MHz 3.55 dB/100ft 330 MHz 3.74 dB/100ft 350 MHz 3.85 dB/100ft
400 MHz 4.15 dB/100ft 450 MHz 4.40 dB/100ft 500 MHz 4.66 dB/100ft 550 MHz 4.90 dB/100ft 600 MHz 5.10 dB/100ft 750 MHz 5.65 dB/100ft 870 MHz 6.11 dB/100ft 1000 MHz 6.55 dB/100ft Electricals 28 Ohm/1000ft 9 Ohm/1000ft (30 Ohm/km) 16.2 pF/ft (53.1 pF/m) 75 Ohm 83% Voltage UL Voltage Rating
300 V (CM)
Mechanical Characteristics Temperature Operating -40°C to +75°C Bend Radius Installation Min. 2.7 in (69 mm) Max. Pull Tension: 150 lbs (68 kg) Bulk Cable Weight: 27 lbs/1000ft Standards and Compliance Environmental Suitability: Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger wire Sustainability: CA Prop 65 Flammability / Reaction to Fire: UL1685 UL Loading CPR Compliance: CPR Euroclass: Eca NEC / UL Compliance: CM, CATV CEC / C(UL) Compliance: CM European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) UK Regulation Compliance: UKCA Mark APAC Compliance: China RoHS II (GB/T 26572-2011) Other Standard Compliance(s): ANSI/SCTE 74 History Update and Revision: Revision Number: 0.473 Revision Date: 04-14-2023 Part Numbers Variants Item # Color Putup Type Length UPC Footnote 1829A 0101000 Black Reel 1,000 ft 612825123910 C 1829A 010U1000 Black UnReel 1,000 ft 612825123903 1829A 0081000 Gray Reel 1,000 ft 612825123873 Z 1829A 008U1000 Gray UnReel 1,000 ft 612825123866 Z 1829A 0091000 White Reel 1,000 ft 612825123897 Z 1829A 009U1000 White UnReel 1,000 ft 612825123880 Z 1829A Q5H1000 White, Neutral Reel 1,000 ft 612825123859 Z 1829A Q5HU1000 White, Neutral UnReel 1,000 ft 612825123842 Z
© 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.