24 AWG stranded (27x38) high-conductivity bare copper conductors, PVC insulation, bare copper spiral

shield (90% coverage), PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 1 24 27x38 High Conductivity BC - Bare Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Material Dia. (mm) PVC - Polyvinyl Chloride 1.4986 Outer Shield Outer Shield Material: Type Outer Shield Material Coverage (%) Spiral Serve BC - Bare Copper 90.000 Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 5.994 mm Pair Pair Color Code Chart: Number Color

1 Blue & Red

Mechanical Characteristics (Overall) Operating Temperature Range: -30°C To +60°C Bulk Cable Weight: 44.646 Kg/Km Max. Recommended Pulling Tension: 44.482 N Min. Bend Radius/Minor Axis: 63.500 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 Page 1 of 2 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1813A Multi-Conductor - Two-Conductor, Low-Impedance Cable

EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Inductance: Inductance (µH/m) 0.718539 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 108.273 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 200.141 Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/km) 74.8068 Nominal Outer Shield DC Resistance: DCR @ 20°C (Ohm/km) 38.0596 Max. Operating Voltage - Non-UL: Voltage

100 V RMS

Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 1813A B591000 305 MT 14.969 KG BLACK, MATTE C 2 #24 PVC SRV PVC 1813A B59328 100 MT 3.422 KG BLACK, MATTE C 2 #24 PVC SRV PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 1 Revision Date: 10-15-2012 © 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 2 of 2 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1813A Multi-Conductor - Two-Conductor, Low-Impedance Cable