16CTU04S_08 VISHAY
Document overview
- Manufacturer or author: Provided By digicamel.com
- PDF pages: 7
Technical content
Document Number: 93929 For technical ques tions, contact: diodes-tech@vishay.com www.vishay.com Revision: 08-Sep-08 1 Ultrafast Rectifier, 2 x 8 A FRED PtTM 16CTU04S/16CTU04-1 Vishay High Power Products
FEATURES
- Ultrafast recovery time Low forward voltage drop Low leakage current 175 °C operating junction temperature Designed and qualified for industrial level DESCRIPTION/APPLICATIONS FRED PtTM series are the state of the art ultrafast recovery rectifiers specifically desi gned with optimized performance of forward voltage drop and ultrafast recovery time. The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in the output rectification stage of SMPS, UPS, dc-to-dc converters as well as freewheeling diode in low voltage inverters and chopper motor drives. Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers. PRODUCT SUMMARY trr 60 ns IF(AV) 2 x 8 A VR 400 V 16CTU04S D2PAK 16CTU04-1 TO-262 Anode 1 3 Base Common Cathode Common Cathode Anode Anode 1 3 Base Common Cathode Common Cathode Anode ABSOLUTE MAXIMUM RATINGS PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS Peak repetitive reverse voltage V RRM 400 V Average rectified forward current per leg IF(AV) A total device Rated V R, TC = 155 °C 16 Non-repetitive peak surge current I FSM TC = 25 °C 100 Peak repetitive forward current I FRM Rated VR, square wave, 20 kHz, TC = 155 °C 16 Operating junction and storage temperatures T J, TStg - 65 to 175 °C ELECTRICAL SPECIFICATIONS PER LEG (TJ = 25 °C unless otherwise specified) PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS Breakdown voltage, blocking voltage VBR, VR IR = 100 µA 400 - - V Forward voltage V F IF = 8 A - 1.19 1.3 IF = 8 A, TJ = 150 °C - 0.94 1.0 Reverse leakage current I R VR = VR rated - 0.2 10 µA TJ = 150 °C, VR = VR rated - 20 500 Junction capacitance C T VR = 400 V - 14 - pF Series inductance L S Measured lead to lead 5 mm from package body - 8.0 - nH
www.vishay.com For technical questi ons, contact: diodes-tech@vishay.com Document Number: 93929
2 Revision: 08-Sep-08
Vishay High Power Products Ultrafast Rectifier, 2 x 8 A FRED PtTM DYNAMIC RECOVERY CHARACTERISTICS PER LEG (TJ = 25 °C unless otherwise specified) PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS Reverse recovery time t rr IF = 1.0 A, dIF/dt = 50 A/µA, VR = 30 V - 35 60 nsTJ = 25 °C IF = 8 A dIF/dt = 200 A/µs VR = 200 V -4 3- TJ = 125 °C - 67 - Peak recovery current I RRM TJ = 25 °C - 2.8 - A Reverse recovery charge Q rr TJ = 25 °C - 60 - nC TJ = 125 °C - 210 - THERMAL - MECHANICAL SPECIFICATIONS PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS Maximum junction and storage temperature range TJ, TStg - 65 - 175 °C Thermal resistance, junction to case per leg RthJC -1 . 8 2 . 0 °C/WThermal resistance, junction to ambient per leg RthJA Typical socket mount - - 50 Thermal resistance, case to heatsink RthCS Mounting surface, flat, smooth and greased -0 . 5- Weight -2 . 0- g -0 . 0 7- o z . Mounting torque 6.0 (5.0) - 12 (10) kgf · cm (lbf · in) Marking device Case style D2PAK 16CTU04S Case style TO-262 16CTU04-1
Document Number: 93929 For technical ques tions, contact: diodes-tech@vishay.com www.vishay.com Revision: 08-Sep-08 3 16CTU04S/16CTU04-1 Ultrafast Rectifier, 2 x 8 A FRED PtTM Vishay High Power Products Fig. 1 - Typical Forward Voltage Drop Characteristics Fig. 2 - Typical Values of Reverse Current vs. Reverse Voltage Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics 100 VF - Forward Voltage Drop (V) IF - Instantaneous Forward Current (A) 0.1 TJ = 175 °C TJ = 150 °C TJ = 25 °C 0.001 0.01 0.1 100 1000 0 100 200 300 400 0.0001 VR - Reverse Voltage (V) IR - Reverse Current (µA) TJ = 175 °C TJ = 150 °C TJ = 125 °C TJ = 100 °C TJ = 25 °C TJ = 25 °C 0 100 200 300 400 1000 100 VR - Reverse Voltage (V) CT - Junction Capacitance (pF) 0.01 0.1 t1 - Rectangular Pulse Duration (s) ZthJC - Thermal Impedance (°C/W) Single pulse (thermal resistance) PDM Notes: 1. Duty factor D = t1/t2 2. Peak TJ = PDM x ZthJC + TC D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01
www.vishay.com For technical questi ons, contact: diodes-tech@vishay.com Document Number: 93929
4 Revision: 08-Sep-08
Vishay High Power Products Ultrafast Rectifier, 2 x 8 A FRED PtTM Fig. 5 - Maximum Allowable Case Temperature vs. Average Forward Current Fig. 6 - Forward Power Loss Characteristics Fig. 7 - Typical Reverse Recovery Time vs. dIF/dt Fig. 8 - Typical Stored Charge vs. dIF/dt Note (1) Formula used: TC = TJ - (Pd + PdREV) x RthJC; Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6); PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = Rated VR See note (1) Square wave (D = 0.50) Rated VR applied DC 0246 8 1210 180 170 160 150 140 130 IF(AV) Average Forward Current (A) Allowable Case Temperature (°C) 0246 8 1210 IF(AV) - Average Forward Current (A) Average Power Loss (W) RMS limit D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5 DC 100 1000 trr (ns) dIF/dt (A/µs) IF = 16 A IF = 8 A VR = 200 V TJ = 125 °C TJ = 25 °C 500 100 1000 Qrr (nC) dIF/dt (A/µs) 100 200 300 400 450 IF = 16 A IF = 8 A 150 250 350 VR = 200 V TJ = 125 °C TJ = 25 °C
Document Number: 93929 For technical ques tions, contact: diodes-tech@vishay.com www.vishay.com Revision: 08-Sep-08 5 16CTU04S/16CTU04-1 Ultrafast Rectifier, 2 x 8 A FRED PtTM Vishay High Power Products Fig. 9 - Reverse Recovery Parameter Test Circuit Fig. 10 - Reverse Recovery Waveform and Definitions IRFP250 D.U.T. L = 70 µH VR = 200 V 0.01 Ω G D S dIF/dt adjust Qrr
0.5 IRRM
dI(rec)M/dt
0.75 IRRM
(1) (2) (3) (4) (5) (1) dIF/dt - rate of change of current through zero crossing (2) IRRM - peak reverse recovery current (3) trr - reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current. (4) Qrr - area under curve defined by trr and IRRM trr x IRRM 2Qrr = (5) dI(rec)M/dt - peak rate of change of current during tb portion of trr
www.vishay.com For technical questi ons, contact: diodes-tech@vishay.com Document Number: 93929
6 Revision: 08-Sep-08
Vishay High Power Products Ultrafast Rectifier, 2 x 8 A FRED PtTM ORDERING INFORMATION TABLE Device code 1 - Current rating (16 A) 2 - C = Common cathode 3 - T = TO-220, D 2PAK 4 - U = Ultrafast recovery 5 - Voltage rating (04 = 400 V) 6 - S = D2PAK -1 = TO-262 7 - None = Tube (50 pieces) TRL = Tape and reel (left oriented, for D2PAK package) TRR = Tape and reel (right oriented, for D2PAK package) 8 - None = Standard production PbF = Lead (Pb)-free 513 24 678
16 C T U 04 S TRL -
LINKS TO RELATED DOCUMENTS Dimensions http://www.vishay.com/doc?95014 Part marking information http://www.vishay.com/doc?95008 Packaging information http://www.vishay.com/doc?95032
Document Number: 91000 www.vishay.com Revision: 18-Jul-08 1 Disclaimer Legal Disclaimer Notice Vishay All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all li ability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permit ted by law. The product specifications do not expand or otherwise modify Vishay’s terms and conditions of purcha se, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medi cal, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners.