1544198 FESTO

Document overview

  • PDF pages: 2

Technical content

Page 1

Bus node CTEU-CC

Part number: 1544198

PDF page 1 diagram

Data sheet

Feature Value
Dimensions W x L x H 40 mm x 91 mm x 50 mm
Type of mounting On electrical interface On electrical sub-base
KC characters KC EMC
Fieldbus interface, protocol CC-LINK®
Note on fieldbus interface Optional connection technology with accessories: Open style (screw terminal, 5-pin, degree of protection: IP20)
Power supply, function Electronics and load
Power supply, connection technology M12x1, A-coded as per EN 61076-2-101
Power supply, type of connection Plug
Fieldbus interface, type Serial interface
Fieldbus interface, function Bus connection, incoming/forwarding
Fieldbus interface, transmission rate 156 - 10000 kbit/s
Fieldbus interface, galvanic isolation yes
Fieldbus interface, connection pattern 00995638
Power supply, connection pattern 00995383
Fieldbus interface, connection technology Sub-D
Fieldbus interface, connection type Socket
Note on degree of protection In mounted state Unused connections sealed
Fieldbus interface, number of poles/wires 9
Power supply, number of pins/wires 5
Width dimension 40 mm
Type code CTEU
Diagnostics Communication error System diagnostics Undervoltage
Additional functions System status can be indicated via process data
Parameterization Activate diagnostics Fail-safe and idle response
Control elements DIL switch
Internal cycle time 1 ms per 1 byte of user data
DC operating voltage range 18 V ... 30 V
Intrinsic current consumption at nominal operating voltage Typ. 70 mA
Max. power supply 4 A
Nominal operating voltage DC 24 V
Protocol CC-LINK®

6/8/21 - Subject to change - Festo AG & Co. KG

1/2

Page 2

Feature Value
CE marking (see declaration of conformity) As per EU EMC directive
Corrosion resistance class (CRC) 2 - Moderate corrosion stress
Storage temperature -20 °C ... 70 °C
Degree of protection IP65 IP67
Ambient temperature -5 °C ... 50 °C
Certification RCM compliance mark c UL us - Listed (OL)
Product weight 90 g
Max. address capacity outputs 16 byte
Max. address capacity inputs 16 byte
LED display (bus-specific) Err: data transmission error Run: bus active
LED display (product-specific) PS: operating voltage for electronics and load supply X1: module system status at I-Port 1 X2: module system status at I-Port 2
Note on materials Contains paint-wetting impairment substances RoHS-compliant
Housing material PA

6/8/21 - Subject to change - Festo AG & Co. KG

2/2