1538050 PHOENIX
Document overview
- Manufacturer or author: Provided By digicamel.com
- PDF pages: 9
Technical content
Please be informed that the data shown in this PDF document is generated from our Online Catalog. Please find the complete data in the user documentation. Our General Terms of Use for Downloads are valid. Bus system cable, PROFIBUS (12 Mbps), 2-position halogen-free, shielded, Plug straight M12, Commercial Data Item number 1538050 Packing unit 1 pc Minimum order quantity 1 pc Note Made to Order (non-returnable) Sales Key BF17 Product Key BF1CKC Catalog Page Page 429 (C-2-2017) Customs tariff number 85444290 Country of origin PL SAC-2P-MSB SCO/910/... - Bus system cable 1538050 https://www.phoenixcontact.com/us/products/1538050 Jul 11, 2023, 4:34 AM Page 1 (9)
Product type Data cable preassembled Sensor type PROFIBUS Number of positions 2 Application Standard No. of cable outlets 1 Shielded yes Coding B Insulation characteristics Overvoltage category II Degree of pollution 3 Interfaces Bus system PROFIBUS Signal type/category PROFIBUS, 12 Mbps (max. 100 m) Signaling Status display No Status display present No Electrical properties Contact resistance ≤ 5 mΩ Insulation resistance ≥ 100 MΩ
48 V ACNominal voltage UN
60 V DC
Transmission medium Copper Mechanical properties Mechanical data Insertion/withdrawal cycles ≥ 100 Material specifications Flammability rating according to UL 94 HB Material of grip body TPU, hardly inflammable, self-extinguishing Contact material CuSn Contact surface material Ni/Au Contact carrier material TPU GF Material for screw connection Zinc die-cast, nickel-plated Connection data SAC-2P-MSB SCO/910/... - Bus system cable 1538050 https://www.phoenixcontact.com/us/products/1538050 Jul 11, 2023, 4:34 AM Page 2 (9)
2 (Plug) | GN (A cable)Contact | Color (signal designation) | Contact (optional) 4 (Plug) | RD (B cable) Connector Connection 1 Type Plug straight M12 SPEEDCON Number of positions 2 Coding type B (inverse) Number of positions 2 Locking type SPEEDCON Connection 2 Type free cable end Cable/line PROFIBUS [910] Dimensional drawing Cable weight 90 kg/km UL AWM Style 21198 (80°C/300 V) Number of positions 2 Shielded yes Cable type PROFIBUS [910] Conductor structure 1x2xAWG24/19 Conductor structure signal line 19x 0.13 mm AWG signal line 24 Conductor cross section 2x 0.25 mm² (Signal line) Wire diameter incl. insulation 2.55 mm ±0.07 mm External cable diameter 7.8 mm ±0.2 mm Outer sheath, material PUR External sheath, color red lilac RAL 4001 Conductor material Tin-plated Cu litz wires Material, filler PP Material wire insulation Foam-Skin PP Single wire, color red, green SAC-2P-MSB SCO/910/... - Bus system cable 1538050 https://www.phoenixcontact.com/us/products/1538050 Jul 11, 2023, 4:34 AM Page 3 (9)
Overall twist 2 cores with 2 fillers to the core Optical shield covering 85 % Max. conductor resistance ≤ 78.6 Ω/km Insulation resistance ≥ 5 GΩ*km Wave impedance 150 Ω ±10 % (3 MHz ... 20 MHz) Cable capacity nom. 30 pF/m Nominal voltage, cable 300 V Test voltage Core/Core 1500 V (50 Hz, 1 min.) Test voltage Core/Shield 1500 V (50 Hz, 1 min.) Smallest bending radius, fixed installation 40 mm Smallest bending radius, movable installation 65 mm 4000000Max. bending cycles 5000000 Shield attenuation ≤ 0.049 dB/m (at 16 MHz) in accordance with DIN VDE 0472 part 815Halogen-free according to IEC 60754-1 UL 1581, Section 1060 and UL 2556, Section 9.3 (FT1) UL 1581, Section 1100 and UL 2556, Section 9.1 (HFT/FT2) Flame resistance IEC 60332-1-2 Other resistance Low adhesion -40 °C ... 80 °C (cable, fixed installation) -30 °C ... 70 °C (Cable, flexible installation) -20 °C ... 60 °C (for installation) Ambient temperature (operation) -20 °C ... 60 °C (cable, drag chain applications) Environmental and real-life conditions Ambient conditions IP65Degree of protection IP67 Ambient temperature (operation) -25 °C ... 90 °C (Plug / socket) Standards and regulations Standards/specifications IEC 61076-2-101 SAC-2P-MSB SCO/910/... - Bus system cable 1538050 https://www.phoenixcontact.com/us/products/1538050 Jul 11, 2023, 4:34 AM Page 4 (9)
Pin assignment M12 male connector, 5-pos., B-coded, male side Circuit diagram GN2 4 RD SAC-2P-MSB SCO/910/... - Bus system cable 1538050 https://www.phoenixcontact.com/us/products/1538050 Jul 11, 2023, 4:34 AM Page 5 (9)
47,3 Ø14,8 M12 SPEEDCON plug, straight, shielded SAC-2P-MSB SCO/910/... - Bus system cable 1538050 https://www.phoenixcontact.com/us/products/1538050 Jul 11, 2023, 4:34 AM Page 6 (9)
To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1538050 UL Listed Approval ID: FILE E 221474 Nominal Voltage UN Nominal Current IN Cross Section AWG Cross Section mm2
300 V 4 A - -
cUL Listed Approval ID: FILE E 221474 Nominal Voltage UN Nominal Current IN Cross Section AWG Cross Section mm2 EAC-RoHS Approval ID: RU D-DE.HB35.B.00387 SAC-2P-MSB SCO/910/... - Bus system cable 1538050 https://www.phoenixcontact.com/us/products/1538050 Jul 11, 2023, 4:34 AM Page 7 (9)
ECLASS-11.0 27060307 ECLASS-12.0 27060307 ECLASS-13.0 27060307 ETIM ETIM 8.0 EC001855 UNSPSC UNSPSC 21.0 26121600 SAC-2P-MSB SCO/910/... - Bus system cable 1538050 https://www.phoenixcontact.com/us/products/1538050 Jul 11, 2023, 4:34 AM Page 8 (9)
Environmental Product Compliance Environmentally friendly use period: unlimited = EFUP-eChina RoHS No hazardous substances above threshold values Phoenix Contact 2023 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com SAC-2P-MSB SCO/910/... - Bus system cable 1538050 https://www.phoenixcontact.com/us/products/1538050 Jul 11, 2023, 4:34 AM Page 9 (9)