151-16500 HELLERMANNTYTON

Document overview

  • Manufacturer or author: Provided By digicamel.com
  • PDF pages: 3

Technical content

1.7 140 Further information at www.HellermannTyton.com/fixings Date of issue: 10/2017 Cable Ties and Fixings Cable Tie Mounts FKH mounts are designed to retain flat ribbon cables commonly used in information technology applications, in entertainment electronics or for connecting sensors. As each installation scenario is individual, FKH mounts are available in different dimensions and can be supplied as self adhesive and/or screwable versions. Features and benefits

  • One-piece fixing mount for flat ribbon cables
  • Increased mounting area ensures proper bonding
  • Quick and easy installation
  • Can be released and re-used easily
  • Flat cable is gently fastened due to soft wings Flat ribbon cable mounts Based on extremely soft wings any flat cable is gently fastened. FKH-Series, self adhesive, screw fixing TYPE Width (W) Length (L) Width (W2) Hole Ø (FH) Material Colour Adhesive Article-No. FKH25A 25.0 31.0 22.0 3.1 PA66HIR Black (BK) Acrylate 151-15250 FKH30A 25.0 35.0 22.0 3.1 PA66HIR Black (BK) Acrylate 151-15300 FKH50A 25.0 56.5 22.0 3.1 PA66HIR Black (BK) Acrylate 151-15500 FKH80A 25.0 86.0 22.0 3.1 PA66HIR Black (BK) Acrylate 151-15800 All dimensions in mm. Subject to technical changes. FKH-Series, screw fixing TYPE Width (W) Length (L) Width (W2) Hole Ø (FH) Material Colour Article-No. FKH25 25.0 31.0 22.0 3.1 PA66HIR Black (BK) 151-16250 FKH30 25.0 35.0 22.0 3.1 PA66HIR Black (BK) 151-16300 FKH50 25.0 56.5 22.0 3.1 PA66HIR Black (BK) 151-16500 FKH80 25.0 86.0 22.0 3.1 PA66HIR Black (BK) 151-16800 All dimensions in mm. Subject to technical changes. L FH Flat Ribbon Cable Mount (side view)Fixing can be realised with M3 screws or acrylic adhesive backing W Flat Ribbon Cable Mount (front view) SolidTack-Series FKH, high performance adhesive TYPE Width (W) Width (W2) Length (L) Hole Ø (FH) For Cable Width max. Material Colour Adhesive Pack Cont. Article-No. All dimensions in mm. Subject to technical changes. Minimum Order Quantity (MOQ) may differ from package content. Other packaging options may also be available. Material specification please see page 26.

1.0 26 Further information at www.HellermannTyton.com/fixings Date of issue: 10/2017 Material Specification Overview Cable Ties and Fixings Material Information MATERIAL Material Shortcut Operating Temperature Colour** Flammability Material Properties* Material Specifications Aluminium-alloy AL -40 °C to +180 °C Natural (NA) • Corrosion resistant

  • Antimagnetic Chloroprene CR -20 °C to +80 °C Black (BK) • W eather-resistant
  • High yield strength Ethylene Tetrafluoroethylene (Tefzel ® ) E/TFE -80 °C to +170 °C Blue (BU) UL 94 V0
  • Resistance to radioactivity
  • UV- resistant, not moisture sensitive
  • Good chemical resistance to: acids, bases, oxidizing agents Polyacetal POM -40 °C to +90 °C, (+110 °C, 500 h) Natural (NA) UL 94 HB
  • Limited brittleness sensitivity
  • Flexible at low temperature
  • Not moisture sensitive
  • Robust on impacts Polyamide 11 PA11 -40 °C to +85 °C, (+105 °C, 500 h) Black (BK) UL 94 HB
  • Bio-plastic, derived from vegetable oil
  • S trong impact resistance at low temperature
  • V ery low moisture absorption
  • W eather-resistant
  • Good chemical resistanc Polyamide 12 PA12 -40 °C to +85 °C, (+105 °C, 500 h) Black (BK) UL 94 HB
  • Good chemical resistance to: acids, bases, oxidizing agents
  • UV- resistant Polyamide 4.6 PA46 -40 °C to +150 °C (5000 h), +195 °C (500 h) Natural (NA), Grey (GY) UL 94 V2
  • Resistance to high temperatures
  • V ery moisture sensitive
  • L ow smoke sensitiv Polyamide 6 PA6 -40 °C to +80 °C Black (BK) UL 94 V2 • High yield strength Polyamide 6, high impact modified PA6HIR -40 °C to +80 °C Black (BK) UL 94 HB
  • Limited brittleness sensitivity
  • Higher flexibility at low temperature Polyamide 6.6 PA66 -40 °C to +85 °C, (+105 °C, 500 h) Black (BK), Natural (NA) UL 94 V2 • High yield strength Polyamide 6.6, glass-fibre reinforced PA66GF13, PA66GF15 -40 °C to +105 °C Black (BK) UL 94 HB
  • Good resistance to: lubricants, vehicle fuel, salt water and a lot of solvent Polyamide 6.6, heat and UV stabilised PA66HSW -40 °C to +105 °C Black (BK) UL 94 V2
  • High yield strength
  • Modified elevated max. temperature
  • UV-resistant Polyamide 6.6, heat stabilised PA66HS -40 °C to +105 °C Black (BK), Natural (NA) UL 94 V2
  • High yield strength
  • Modified elevated max. temperature Polyamide 6.6, high impact modified PA66HIR -40 °C to +80 °C, (+105 °C, 500 h) Black (BK) UL 94 HB
  • Limited brittleness sensitivity
  • Higher flexibility at low temperature Polyamide 6.6, high impact modified, heat and UV stabilised PA66HIRHSW -40 °C to +110 °C Black (BK) UL 94 HB
  • Limited brittleness sensitivity
  • Higher flexibility at low temperature
  • Modified elevated max. temperature
  • High yield strength, UV-resistant Polyamide 6.6, high impact modified, heat stabilised PA66HIRHS -40 °C to +105 °C Black (BK) UL 94 HB
  • Limited brittleness sensitivity
  • Higher flexibility at low temperature
  • Modified elevated max. temperature Polyamide 6.6, high impact modified, ScanBlack PA66HIR(S) -40 °C to +80 °C, (+105 °C, 500 h) Black (BK) UL 94 HB
  • Limited brittleness sensitivity
  • Higher flexibility at low temperature Polyamide 6.6, UV-resistant PA66W -40 °C to +85 °C, (+105 °C, 500 h) Black (BK) UL 94 V2 • High yield strength
  • UV-resistant

1.0 27Further information at www.HellermannTyton.com/fixings Date of issue: 10/2017 Cable Ties and Fixings Material Information MATERIAL Material Shortcut Operating Temperature Colour** Flammability Material Properties* Material Specifications Polyamide 6.6, with metal particles PA66MP -40 °C to +85 °C, (+105 °C, 500 h) Blue (BU) UL 94 HB • High yield strength

  • Metal and X-Ray detectable Polyamide 6.6, with metal particles PA66MP+ -40 °C to +85 °C Blue (BU) not flame retardant
  • High yield strength
  • Metal and x-ray detectable Polyamide 6.6 V0 PA66V0 -40 °C to +85 °C White (WH) UL 94 V0 • High yield strength
  • L ow smoke emission Polyester SP -50 °C to +150 °C Black (BK) halogen free
  • UV-resistant
  • Good chemical resistance to: most acids, alkaliks and oils Polyetheretherketone PEEK -55 °C to +240 °C Beige (BGE) UL 94 V0
  • Resistance to radioactivity
  • Not moisture sensitive
  • Good chemical resistance to: acids, bases, oxidizing agents Polyethylene PE -40 °C to +50 °C Black (BK), Grey (GY) UL 94 HB
  • L ow moisture absorption
  • Good chemical oilsresistance to: most acids, alcohol and oils Polyolefin PO -40 °C to +90 °C Black (BK) UL 94 V0 • L ow smoke emissions Polypropylene PP -40 °C to +115 °C Black (BK), Natural (NA) UL 94 HB
  • Floats in water
  • Moderate yield strength
  • Good chemical resistance to: organic acids Polypropylene, Ethylene-Propylene- Dien-Terpolymere- rubber free of Nitrosamine PP , EPDM -20 °C to +95 °C Black (BK) UL 94 HB
  • Good resistance to high temperatures
  • Good chemical and abrasion resistance Polypropylene with metal particles PPMP -40 °C to +115 °C Blue (BU) UL 94 HB
  • Metal and X-Ray detectable
  • Heat resistant
  • Moderate yield strength
  • Good chemical resistance Polypropylene with metal particles PPMP+ -40 °C to +85 °C Blue (BU) not flame retardant
  • High yield strength
  • Metal and x-ray detectable Polyvinylchloride PVC -10 °C to +70 °C Black (BK), Natural (NA) UL 94 V0
  • L ow moisture absorption
  • Good chemical resistance to: acids, ethanol and oil Stainless Steel SS304, SS316 -80 °C to +538 °C Natural (NA) non-burning
  • Corrosion resistant
  • Antimagnetic
  • W eather resistant
  • Outstanding chemical resistance Thermoplastic Polyurethane TPU -40 °C to +85 °C Black (BK) UL 94 HB
  • High elastic
  • Good chemical resistance to: acids, bases and oxidizing agents Tefzel ® is a registered trademark of DuPont. General linguistic usage for cable ties made from raw material E/TFE is Tefzel ® -Tie. In additon to Tefzel ® from DuPont HellermannTyton is also using equivalent E/TFE raw material from other suppliers. **More colours on request. * These details are only rough guide values. They should not be regarded as a material specification and are no substitute for a suitability test. Please see our datasheets for further details. HF = Halogenfree LFH = Limited Fire Hazard RoHS = Restriction of Hazardous Substances