1367338 PHOENIX
Document overview
- Manufacturer or author: Provided By digicamel.com
- PDF pages: 16
Technical content
Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Patch cable, degree of protection: IP20, cable length: 2 m, number of positions: 8, 10 Gbps, CAT6A, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet Your advantages Perfect for office, building, and protected industrial applications (e.g., in control cabinets)• Worldwide approval with CE, UL, WEEE, and EAC Secure connection and disconnection with reliable locking clip protection Ideal EMC properties, thanks to 360° shielding Simultaneous power transmission with PoE++ Future-proof high-speed data transmission with up to 10 Gbps (CAT6<sub>A</sub>) Commercial data Item number 1367338 Packing unit 1 pc Minimum order quantity 10 pc Product key ABNABH GTIN 4063151720087 Weight per piece (including packing) 117.7 g Weight per piece (excluding packing) 22.22 g Country of origin CN NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 1 (16)
Product type Data cable preassembled Sensor type Ethernet Number of positions 8 Shielded yes Cable outlet straight Insulation characteristics Overvoltage category I Degree of pollution 2 Electrical properties Rated voltage (III/2) 72 V Transmission speed 10 Gbps Power transmission PoE++ Mechanical properties Mechanical data Insertion force per signal contact 30.00 N Extraction force per signal contact 50 N Material specifications Flammability rating according to UL 94 V0 Contact material Brass Contact surface material Au Contact carrier material PC Outer sheath, material LSZH Dimensions Width 11.6 mm Height 14.8 mm Length 40 mm Connection data Connection technology Connection method Pierce connection Conductor connection Connection method Pierce connection Connector NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 2 (16)
Insertion/withdrawal cycles ≥ 750 Degree of protection IP20 Number of positions 8 Insertion/withdrawal cycles 750 Connection 2 Type Plug straight RJ45 Shielded yes Handle color gray Insertion/withdrawal cycles ≥ 750 Ambient temperature (operation) -20 °C ... 80 °C Number of positions 8 Degree of protection IP20 Cable/line Cable length 2.00 m Ethernet, Type B, 8-pos., CAT6A, LSZH [BC6A] Shielded yes Cable type Ethernet, Type B, 8-pos., CAT6A, LSZH Cable type (abbreviation) BC6A Cable structure 4x2xAWG26/7; S/FTP External cable diameter 6.5 mm ±0.3 mm Outer sheath, material LSZH External sheath, color gray Thickness, outer sheath approx. 0.7 mm Conductor material Bare Cu litz wires Conductor structure signal line 7x 0.16 mm AWG signal line 26 Material wire insulation PE Single wire, number of litz wires 8 Wire diameter incl. insulation 1 mm Single wire, cross section [AWG] 26 Shielding S/FTP Optical shield covering 70 % Cable insulation resistance ≥ 5000 MΩ*km Wave impedance 100 Ω Loop resistance ≤ 148.00 Ω/km Minimum bending radius, fixed installation 8 x D 3.1 dB (with 1 MHz) 5.7 dB (at 4 МHz) Damping NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 3 (16)
8.9 dB (at 10 MHz) 11.2 dB (at 16 MHz) 12.6 dB (at 20 МHz) 15.8 dB (at 31.25 МHz) 22.5 dB (at 62.5 МHz) 28.7 dB (at 100 MHz) 41.4 dB (at 200 MHz) 51.4 dB (at 300 MHz) 60.1 dB (at 400 MHz) 67.9 dB (at 500 MHz) 75 dB (with 1 MHz) 66.3 dB (at 4 МHz) 60.3 dB (at 10 MHz) 57.2 dB (at 16 MHz) 55.8 dB (at 20 МHz) 52.9 dB (at 31.25 МHz) 48.4 dB (at 62.5 МHz) 45.3 dB (at 100 MHz) 40.8 dB (at 200 MHz) 38.1 dB (at 300 MHz) 36.3 dB (at 400 MHz) Near end crosstalk attenuation (NEXT) 34.8 dB (at 500 MHz) 72.3 dB (with 1 MHz) 63.3 dB (at 4 МHz) 58.8 dB (at 8 МHz) 57.3 dB (at 10 MHz) 54.2 dB (at 16 MHz) 52.8 dB (at 20 МHz) 51.3 dB (at 25 MHz) 49.9 dB (at 31.25 МHz) 45.4 dB (at 62.5 МHz) 42.3 dB (at 100 MHz) 37.8 dB (at 200 MHz) 35.1 dB (at 300 MHz) 33.3 dB (at 400 MHz) Power-summated near end crosstalk attenuation (PSNEXT) 31.8 dB (at 500 MHz) 20 dB (with 1 MHz) 23 dB (at 4 МHz) 24.5 dB (at 8 МHz) 25 dB (at 10 MHz) 25 dB (at 16 MHz) 25 dB (at 20 МHz) 24.2 dB (at 25 MHz) 23.3 dB (at 31.25 МHz) Return loss (RL) NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 4 (16)
20.7 dB (at 62.5 МHz) 19 dB (at 100 MHz) 16.4 dB (at 200 MHz) 15.6 dB (at 300 MHz) 15.6 dB (at 400 MHz) 15.6 dB (at 500 MHz) Halogen-free complying with IEC 60754-1/2 Flame resistance IEC 60332-1-2/IEC 60332-3-24/CM -20 °C ... 80 °C (Cable, flexible installation)Ambient temperature (operation) -20 °C ... 80 °C (cable, fixed installation) Environmental and real-life conditions Ambient conditions Degree of protection IP20 Ambient temperature (operation) -20 °C ... 80 °C Ambient temperature (storage/transport) 0 °C ... 40 °C Standards and regulations Flame resistance IEC 60332-1-2 NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 5 (16)
To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1367338 EAC Approval ID: 19060508 UL Listed Approval ID: FILE E 335024 cUL Listed Approval ID: FILE E 335024 cULus Listed NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 6 (16)
ECLASS-11.0 27060308 ECLASS-12.0 27060308 ECLASS-13.0 27060308 ETIM ETIM 8.0 EC002599 NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 7 (16)
NBC-R4OC/0,3-BC6A/R4OC - Patch cable 1227572 https://www.phoenixcontact.com/us/products/1227572 Patch cable, degree of protection: IP20, cable length: 0.3 m, number of positions: 8, 10 Gbps, CAT6A, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/0,5-BC6A/R4OC - Patch cable 1227573 https://www.phoenixcontact.com/us/products/1227573 Patch cable, degree of protection: IP20, cable length: 0.5 m, number of positions: 8, 10 Gbps, CAT6A, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 8 (16)
NBC-R4OC/1,0-BC6A/R4OC - Patch cable 1227575 https://www.phoenixcontact.com/us/products/1227575 Patch cable, degree of protection: IP20, cable length: 1 m, number of positions: 8, 10 Gbps, CAT6A, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/1,5-BC6A/R4OC - Patch cable 1227578 https://www.phoenixcontact.com/us/products/1227578 Patch cable, degree of protection: IP20, cable length: 1.5 m, number of positions: 8, 10 Gbps, CAT6A, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 9 (16)
NBC-R4OC/2,0-BC6A/R4OC - Patch cable 1227580 https://www.phoenixcontact.com/us/products/1227580 Patch cable, degree of protection: IP20, cable length: 2 m, number of positions: 8, 10 Gbps, CAT6A, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/3,0-BC6A/R4OC - Patch cable 1227581 https://www.phoenixcontact.com/us/products/1227581 Patch cable, degree of protection: IP20, cable length: 3 m, number of positions: 8, 10 Gbps, CAT6A, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 10 (16)
NBC-R4OC/5,0-BC6A/R4OC - Patch cable 1227583 https://www.phoenixcontact.com/us/products/1227583 Patch cable, degree of protection: IP20, cable length: 5 m, number of positions: 8, 10 Gbps, CAT6A, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/7,5-BC6A/R4OC - Patch cable 1227585 https://www.phoenixcontact.com/us/products/1227585 Patch cable, degree of protection: IP20, cable length: 7.5 m, number of positions: 8, 10 Gbps, CAT6A, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 11 (16)
NBC-R4OC/10,0-BC6A/R4OC - Patch cable 1227588 https://www.phoenixcontact.com/us/products/1227588 Patch cable, degree of protection: IP20, cable length: 10 m, number of positions: 8, 10 Gbps, CAT6A, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/0,3-BC5/R4OC - Patch cable 1227558 https://www.phoenixcontact.com/us/products/1227558 Patch cable, degree of protection: IP20, cable length: 0.3 m, number of positions: 8, CAT5, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 12 (16)
NBC-R4OC/0,5-BC5/R4OC - Patch cable 1227559 https://www.phoenixcontact.com/us/products/1227559 Patch cable, degree of protection: IP20, cable length: 0.5 m, number of positions: 8, CAT5, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/1,0-BC5/R4OC - Patch cable 1227560 https://www.phoenixcontact.com/us/products/1227560 Patch cable, degree of protection: IP20, cable length: 1 m, number of positions: 8, CAT5, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 13 (16)
NBC-R4OC/1,5-BC5/R4OC - Patch cable 1227561 https://www.phoenixcontact.com/us/products/1227561 Patch cable, degree of protection: IP20, cable length: 1.5 m, number of positions: 8, CAT5, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/2,0-BC5/R4OC - Patch cable 1227562 https://www.phoenixcontact.com/us/products/1227562 Patch cable, degree of protection: IP20, cable length: 2 m, number of positions: 8, CAT5, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 14 (16)
NBC-R4OC/3,0-BC5/R4OC - Patch cable 1227563 https://www.phoenixcontact.com/us/products/1227563 Patch cable, degree of protection: IP20, cable length: 3 m, number of positions: 8, CAT5, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/5,0-BC5/R4OC - Patch cable 1227564 https://www.phoenixcontact.com/us/products/1227564 Patch cable, degree of protection: IP20, cable length: 5 m, number of positions: 8, CAT5, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 15 (16)
NBC-R4OC/7,5-BC5/R4OC - Patch cable 1227565 https://www.phoenixcontact.com/us/products/1227565 Patch cable, degree of protection: IP20, cable length: 7.5 m, number of positions: 8, CAT5, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet NBC-R4OC/10,0-BC5/R4OC - Patch cable 1227566 https://www.phoenixcontact.com/us/products/1227566 Patch cable, degree of protection: IP20, cable length: 10 m, number of positions: 8, CAT5, connection method: Pierce connection, connection cross section: AWG 26- 26, cable outlet: straight, Ethernet Phoenix Contact 2023 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com NBC-R4OC/2,0-BC6A/R4OC-BL - Patch cable 1367338 https://www.phoenixcontact.com/us/products/1367338 Oct 10, 2023, 5:54 AM Page 16 (16)