Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Device connector front mounting, PROFINET CAT5 (IEC 11801:2002), 4-position, Pin, straight, M12-SPEEDCON, coding: D, on free cable end, Front mounting, M16 x 1.5, Individual wires, cable length: 0.5 m, 0.34 mm2, TPE litz wire, Item is lead-free in accordance with RoHS II without Exemption 6c (Pb <0.1%) Your advantages Preassembled with litz wires for immediate use• Customer-specific assemblies and litz wire lengths available Sealed on the litz wire side for optimum leak-tightness All standard pin assignments and codings for signal, data, and power transmission with a uniform design-in design For high transmission safety: shield connection to the housing with optional EMC nut SPEEDCON fast locking system reduces cabling times Commercial data Item number 1240008 Packing unit 1 pc Minimum order quantity 1 pc Product key ABQCEB GTIN 4063151394967 Weight per piece (including packing) 24.1 g Weight per piece (excluding packing) 23.8 g Country of origin DE SACC-EC-MSD-4CON-M16/0,5 SCOX - Device connector front mounting 1240008 https://www.phoenixcontact.com/us/products/1240008 Jan 15, 2024, 7:52 AM Page 1 (11)
General The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. General Lock nut is included in the scope of delivery Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
- WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
- WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
- The products are suitable for applications in plant, controller, and electrical device engineering.
- When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
- Assembled products may not be manipulated or improperly opened.
- Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
- When using the product in direct connection with third-party manufacturers, the user is responsible.
- For operating voltages > 50 V AC, conductive connector housings must be grounded
- Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
- Observe the corresponding technical data. You will find information: o On the product o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product
- Only use tools recommended by Phoenix Contact
- Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory Safety note SACC-EC-MSD-4CON-M16/0,5 SCOX - Device connector front mounting 1240008 https://www.phoenixcontact.com/us/products/1240008 Jan 15, 2024, 7:52 AM Page 2 (11)
section of the product at phoenixcontact.com/products
- Ensure that the protective or functional ground has been properly connected. are applicable when combining several circuits in a cable and/or connector
- The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). Mounting Mounting type Front mounting M16 x 1.5 can be positioned Assembly instructions can be positioned Connection method Individual wires Product properties Product type Circular connectors (device side) Sensor type PROFINET Number of positions 4 Application Signal No. of cable outlets 1 Shielded no Coding D Thread type M12 Insulation characteristics Overvoltage category II Degree of pollution 3 Material specifications Flammability rating according to UL 94 V0 Seal material NBR Material of grip body Zinc die-cast, nickel-plated Contact material CuZn Contact surface material Ni/Au Contact carrier material PA 6.6 Material for screw connection Zinc die-cast, nickel-plated Conductor material Tin-plated Cu litz wires Electrical properties Rated surge voltage 2.5 kV Contact resistance ≤ 3 mΩ Insulation resistance ≥ 100 MΩ
250 V (AC)Nominal voltage UN
SACC-EC-MSD-4CON-M16/0,5 SCOX - Device connector front mounting 1240008 https://www.phoenixcontact.com/us/products/1240008 Jan 15, 2024, 7:52 AM Page 3 (11)
250 V (DC)
Transmission medium Copper Transmission characteristics (category) CAT5 (IEC 11801:2002) Max. conductor resistance 57.6 mΩ/m Connection data Conductor connection Connection method Individual wires Contact connection type Pin Conductor cross section 0.34 mm²
3 NmTightening torque
Insertion/withdrawal cycles > 100 Connector Connection 1 Head design Pin Head cable outlet straight Head thread type M12 Head locking type SPEEDCON Coding D Connection 2 Head design free cable end Cable/line Cable length 0.5 m Cable type TPE litz wire Signal type/category PROFINET CAT5 (IEC 11801:2002) Wire diameter incl. insulation 1.2 mm ±0.07 mm Single wire, color yellow, orange, white, blue Cable cross section 0.34 mm² Conductor material Tin-plated Cu litz wires Conductor structure signal line 7x 0.25 mm AWG signal line 22 Material wire insulation TPE Thickness, insulation 0.21 mm Nominal voltage, cable 300 V SACC-EC-MSD-4CON-M16/0,5 SCOX - Device connector front mounting 1240008 https://www.phoenixcontact.com/us/products/1240008 Jan 15, 2024, 7:52 AM Page 4 (11)
Test voltage, cable 2000 V AC Cable resistance ≤ 57.6 mΩ/m Cable insulation resistance ≥ 20 MΩ*km -40 °C ... 85 °C (cable, fixed installation)Ambient temperature (operation) -25 °C ... 85 °C (Cable, flexible installation) Environmental and real-life conditions Ambient conditions IP67Degree of protection IP67 -25 °C ... 85 °C (Plug / socket) -40 °C ... 85 °C (without mechanical actuation) -25 °C ... 85 °C (Cable, flexible installation) Ambient temperature (operation) -40 °C ... 85 °C (cable, fixed installation) Standards and regulations M12 Standard designation M12 connector Standards/specifications according to IEC 61076-2-101 SACC-EC-MSD-4CON-M16/0,5 SCOX - Device connector front mounting 1240008 https://www.phoenixcontact.com/us/products/1240008 Jan 15, 2024, 7:52 AM Page 5 (11)
M16x1,5 M12x1 500 ≥2,5 Dimensional drawing Diagram 0 10 20 30 40 50 60 70 80 90 100 110 120 130 I [A] [°C] = 4x0,34mm 2 1 I = current strength, T = ambient temperature SACC-EC-MSD-4CON-M16/0,5 SCOX - Device connector front mounting 1240008 https://www.phoenixcontact.com/us/products/1240008 Jan 15, 2024, 7:52 AM Page 6 (11)
Pin assignment M12 male connector, 4-pos., D-coded, male side SACC-EC-MSD-4CON-M16/0,5 SCOX - Device connector front mounting 1240008 https://www.phoenixcontact.com/us/products/1240008 Jan 15, 2024, 7:52 AM Page 7 (11)
To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1240008 UL Recognized Approval ID: E118976-20100522 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2
250 V 4 A - 22 -
cULus Recognized Approval ID: E221474-20140616 Nominal voltage UN Nominal current IN Cross section AWG Cross section mm2
250 V 4 A 22 - 20 -
SACC-EC-MSD-4CON-M16/0,5 SCOX - Device connector front mounting 1240008 https://www.phoenixcontact.com/us/products/1240008 Jan 15, 2024, 7:52 AM Page 8 (11)
ECLASS-11.0 27440102 ECLASS-12.0 27440116 ECLASS-13.0 27440116 ETIM ETIM 9.0 EC002635 SACC-EC-MSD-4CON-M16/0,5 SCOX - Device connector front mounting 1240008 https://www.phoenixcontact.com/us/products/1240008 Jan 15, 2024, 7:52 AM Page 9 (11)
Environmental product compliance Environmentally friendly use period: unlimited = EFUP-eChina RoHS No hazardous substances above threshold values SACC-EC-MSD-4CON-M16/0,5 SCOX - Device connector front mounting 1240008 https://www.phoenixcontact.com/us/products/1240008 Jan 15, 2024, 7:52 AM Page 10 (11)
SACC-M16-SEAL CLM - Flat gasket 1430394 https://www.phoenixcontact.com/us/products/1430394 M16 flat gasket for M12 flush-type connectors with M16 fastening thread PROT-M12 FS - Sealing cap 1560251 https://www.phoenixcontact.com/us/products/1560251 M12 sealing cap for unoccupied M12 plugs of the sensor/actuator cable, flush- type plugs and I/O devices in the field Phoenix Contact 2024 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com SACC-EC-MSD-4CON-M16/0,5 SCOX - Device connector front mounting 1240008 https://www.phoenixcontact.com/us/products/1240008 Jan 15, 2024, 7:52 AM Page 11 (11)