Thermal Automotive Circuit Breaker 1160-... www.e-t-a.de1942

Description

Ordering information

Standard current ratings and typical voltage drop values Technical data Thermal circuit breaker, with controlled self-resetting mechanism, specially suited to installation in inaccessible locations. Under overload conditions the circuit breaker contacts will open to protect the load circuit. A low current excitation circuit ensures that the contacts remain open thereby avoiding the hazards of automatic reset operation. The circuit breaker is reset by switching off the supply circuit for a short period. Class 2 device, contacts stay open until voltage is removed. Type II to SAE J 553. Automotive and marine extra low voltage wiring systems and components, battery powered appliances. 1160-... Nähere Erläuterungen siehe: www.e-t-a.de/ti_d Voltage rating DC 12 V Current ratings 12...30 A Typical life 300 operations at 2 x IN Holding current < 0.6 A Reset time at 23°C after 5 s of load with UN < 35 sec Interrupting capacity (o-o-o) 200 A, L/R = 2.5 ms Degree of protection housing area IP54 (IEC 60529/DIN 40050) terminal area IP00 Vibration 5 g (57-500 Hz) ± 0.38 mm (10-57 Hz), to IEC 60068-2-6, test Fc, 10 frequency cycles/axis Shock 25 g (11 ms) to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Mass approx. 6 g Type No. 1160 single pole plug-in type Design standard 02 standard version 12 V Current ratings 12, 15, 20, 30 A 1160 - 02 - 12A ordering example Please be informed that we have minimum ordering quantities to be observed. Current rating (A) Voltage drop (mV) 12 < 150 15 < 150 20 < 150 30 < 150

Thermal Automotive Circuit Breaker 1160-... www.e-t-a.de 1942 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient temperature °F -20 +14 -10 +32 +73.4 +23 +104 +40 +122 +50 +140 +60 12 4 6 81 02 0 40 Trip time in seconds ... times rated current 10000 1000 100 0.1 0.6 0.8 .988 .937 .366 .205 .098 .031 .299 .087 .362 .390 .689 23.8 25.1 9.3 5.2 17.5s 2.2 7.6 2.5 0.8 9.2 9.9 Dimensions Accessories Internal connection diagram Typical time/current characteristics at +23 °C/+73.4 °F Sockets available to special order. This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted.