5520 EXTREMENETWORKS

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(free datasheet download site)
  • PDF pages: 17

Technical content

  • Fixed 24 and 48-port switches with gigabit and multi-gigabit support
  • Choice of operating system (OS) with universal dual-persona hardware
  • Intuitive and centralized cloud- based network management with ExtremeCloud™ IQ and ExtremeCloud IQ Site Engine
  • Fabric-enabled operations with Extreme Fabric Connect for simplified and secure network provisioning and automation
  • Front to back cooling and AC power supply input on all models
  • Back to front cooling and DC power supply input option on spec ific models
  • AC and DC Power Supply Unit (PSU) capable SKUs Key Hardware Features
  • Choice of 10Gb and 25Gb modular uplink ports
  • 30W, 60W and 90W PoE support for powering connected devices
  • 200Gb per unit stacking of up to eight switches
  • Hot-swappable, redundant power supplies and fans
  • MACsec on access and modular uplink ports for secure link encryption
  • Extended Edge Switching controlling bridge in support of V300/V400 edge devices
  • Non-blocking, wire-speed design Universal Edge/Aggregation Switch Platform The 5520 Series is a family of high-performance, feature-rich edge and aggregation switches designed for the next-generation digital enterprise. Available in 24 and 48-port 1 Gigabit models, 1/2.5/5 Gigabit multi-rate models, as well as, a 24-port 10 Gigabit model, the 5520 Series provides end-to-end secure network segmentation and advanced policy capabilities that can be deployed across a range of edge, aggregation, and wiring closet environments. As a universal hardware platform, the 5520 offers a user-selectable choice of Extreme’s flagship switch operating systems for a uniquely fle xible platform. The 5520 supports 10Gb and 25Gb modular uplinks for fle xible linkage to other switches or devices over a range of media. Extended Edge Switching controlling bridge is also available in support of V300/V400 edge devices, and select models offer a choice between Front to Back or Back to Front cooling. The 5520 Series offers 30W, 60W, and 90W PoE, making it an ideal wired backend for wireless APs or in support of next-gen powered Ethernet devices, such as digital signage, pan-tilt-zoom cameras, smart lighting, or point-of-sale terminals. Data Sheet

5520 Series

www.extremenetworks.com 1

Universal Hardware Platform The 5520 comes with a dual-persona capability, allowing you to choose your OS. Either the Switch Engine (EXOS)1 or Fabric Engine (VOSS)2 OS can be selected at switch start-up or changed at a later stage. When selected, the switch assumes the features and capabilities of that OS.

5520 OS selection can also be automated with ExtremeCloud IQ so that

the desired OS can be automatically loaded at switch start-up, facilitating remote OS enablement.

1 Switch Engine is the new name for ExtremeXOS (EXOS) on all universal

switch platforms, starting with Version 31.6.

2 Fabric Engine is the new name for the VSP Operating System Software

(VOSS) on all universal switch platforms, starting with Version 8.6. Cloud-Based Network Management The 5520 can be managed by ExtremeCloud IQ and ExtremeCloud IQ Site Engine for centralized switch management, giving you a consolidated view of users, devices, and applications across wired and wireless networks for effic ient inventory and network topology management. ExtremeCloud IQ enables zero touch provisioning, allowing you to quickly bring new 5520 switches online as well as select the OS persona. Alternatively, 5520 on-box management can be done manually via a web- based GUI or generic command-line interface (CLI). Ethernet Fabric Services The 5520 supports a variety of Ethernet Fabric services, including Extreme’s Fabric Connect when running Fabric Engine and Extreme’s IP Fabric when running Switch Engine. It also supports Fabric Attach for automated connection to either Layer 2 or Layer 3 Fabric services. Extreme’s Fabric Connect and IP Fabric enable the creation of virtualized networks that automate network operations, simplify network provisioning, and enhance security, all while reducing the strain on network and IT personnel. Power over Ethernet (PoE) All 5520 models support 30W, 60W, and 90W PoE that conforms with IEEE 802.3bt. This enables the 5520 to address the needs of powered edge devices, while eliminating the need for additional electrical cabling and circuits. In addition, 5520 PoE models support perpetual and fast PoE for even more effic ient and reliable powered edge device operation VIM Options for Flexible Uplinks The 5520 supports Versatile Interface Modules (VIMs), providing fle xible uplink capabilities with a single VIM slot. VIM options include four-port 10Gb or 25Gb modules that include LRM and 256-bit MACsec support. High-Performance Stacking The 5520 Series supports high-speed 200Gb* stacking when running Switch Engine via its two built-in QSFP28 stacking ports. Up to eight systems can be stacked using qualified QSFP+ direct attach cables and optical transceivers. *200Gb stacking available with Switch Engine 31.6 Audio Video Bridging The 5520 series supports IEEE 802.1 Audio Video Bridging (AVB) when running Switch Engine OS. This allows 5520 models to deliver reliable, real- time audio/video transmission over Ethernet, meeting the quality of service required for today’s high- definition, time-sensitive multimedia streams. www.extremenetworks.com 2

5520-24T • 24 x 10/100/1000BASE-T ports ◦ Full / Half-Duplex (autosensing) ◦ MACsec-capable

  • 2 x Stacking/QSFP28 ports* (unpopulated)
  • 1 x Serial console port (RJ-45)
  • 1 x 10/100/1000BASE-T out-of-band management port
  • 2 x USB A ports for management or external USB flash
  • 1 x USB Micro-B console port
  • 1 x VIM slot 5520-24W • 24 x 10/100/1000BASE-T 802.3bt (90W) ports ◦ Full / Half-Duplex (autosensing) ◦ MACsec-capable
  • 2 x Stacking/QSFP28 ports* (unpopulated)
  • 1 x Serial console port (RJ-45)
  • 1 x 10/100/1000BASE-T out-of-band management port
  • 2 x USB A ports for management or external USB flash
  • 1 x USB Micro-B console port
  • 1 x VIM slot 5520-48T • 48 x 10/100/1000BASE-T ports ◦ Full / Half-Duplex (autosensing) ◦ MACsec-capable
  • 2 x Stacking/QSFP28 ports* (unpopulated)
  • 1 x Serial console port (RJ-45)
  • 1 x 10/100/1000BASE-T out-of-band management port
  • 2 x USB A ports for management or external USB flash
  • 1 x USB Micro-B console port
  • 1 x VIM slot 5520-48W • 48 x 10/100/1000BASE-T 802.3bt (90W) ports ◦ Full / Half-Duplex (autosensing) ◦ MACsec-capable
  • 2 x Stacking/QSFP28 ports* (unpopulated)
  • 1 x Serial console port (RJ-45)
  • 1 x 10/100/1000BASE-T out-of-band management port
  • 2 x USB A ports for management or external USB flash
  • 1 x USB Micro-B console port
  • 1 x VIM slot 5520-12MW-36W • 12 x 100M/1/2.5/5GBASE-T 802.3bt (90W) PoE ports
  • 36 x 10/100/1000BASE-T 802.3bt (90W) PoE ports ◦ Full-Duplex ◦ MACsec-capable
  • 2 x Stacking/QSFP28 ports* (unpopulated)
  • 1 x Serial console port (RJ-45)
  • 1 x 10/100/1000BASE-T out-of-band management port
  • 2 x USB A ports for management or external USB flash
  • 1 x USB Micro-B console port
  • 1 x VIM slot www.extremenetworks.com 3

5520-48SE • 48 x 100/1000BASE-X (SFP) ports (unpopulated) ◦ MACsec-capable

  • 2 x Stacking/QSFP28 ports* (unpopulated)
  • 1 x Serial console port (RJ-45)
  • 1 x 10/100/1000BASE-T out-of-band management port
  • 2 x USB A ports for management or external USB flash
  • 1 x USB Micro-B console port
  • 1 x VIM slot 5520-24X • 24 x 100M/1G/10GBASE-X (SFP+) ports** (unpopulated)
  • 2 x Stacking/QSFP28 ports* (unpopulated)
  • 1 x Serial console port (RJ-45)
  • 1 x 10/100/1000BASE-T out-of-band management port
  • 2 x USB A ports for management or external USB flash
  • 1 x USB Micro-B console port
  • 1 x VIM slot 5520-24T-ACDC • 24 x 10/100/1000BASE-T FDX/HDX MACsec capable ports
  • 2 stacking/QSFP28 ports
  • 1 unpopulated VIM slot
  • 3 unpopulated modular fan slots
  • 2 unpopulated modular PSU slots
  • AC or DC PSU capable 5520-48T-ACDC • 48 x 10/100/1000BASE-T FDX/HDX MACsec capable ports
  • 2 stacking/QSFP28 ports
  • 1 unpopulated VIM slot
  • 3 unpopulated modular fan slots
  • 2 unpopulated modular PSU slots
  • AC or DC PSU capable 5520-24X-ACDC • 24 x 100M/1Gb/10Gb SFP+ ports** (unpopulated)
  • 2 stacking/QSFP28 ports (unpopulated)
  • 1 unpopulated VIM slot
  • 3 unpopulated modular fan slots
  • 2 unpopulated modular PSU slots
  • AC or DC PSU capable 5520-48SE-ACDC • 48 x 100/1000BASE-X SFP MACsec capable ports (unpopulated)
  • 2 stacking/QSFP28 ports (unpopulated)
  • 1 unpopulated VIM slot
  • 3 unpopulated modular fan slots
  • 2 unpopulated modular PSU slots
  • AC or DC PSU capable 5520-VIM-4X • 4 x 1/10GBASE-X SFP+ ports (unpopulated) 5520-VIM-4XE • 4 x 1/10GBASE-X SFP+ ports (unpopulated) ◦ LRM-capable ◦ MACsec-capable 5520-VIM-4YE • 4 x 10/25GBASE-X SFP28 ports (unpopulated) ◦ MACsec-capable www.extremenetworks.com 4
  • Notes on use of the 2 x Stacking/QSFP28 ports 1. With Switch Engine, the 2 x QSFP28 ports can be used for stacking or as Ethernet uplink ports (when not stacking); stacking data rate is 40Gb or 50Gb per port. 2. With Fabric Engine, the 2 x QSFP28 ports can be used as Ethernet uplink ports if in non-Fabric mode or if no VIM is present as of the VOSS 8.4.2 release. 3. Ethernet uplink QSFP28 data rate options per port, with channelization: 4 x 10Gb SFP+, 4 x 25Gb SFP28, 1 x 40Gb QSFP+ (supported with Switch Engine and Fabric Engine); 2 x 50Gb (Switch Engine only) ** 100M on 5520-24x and 5520-24x-ACDC access ports supported with Switch Engine and with Fabric Engine. Refer to the Extreme Optics Compatibility Tool. Performance and Scale Switch Model Max Active 10Mb/ 100Mb/ 1000Mb ports Max Active 100Mb/1Gb/ 2.5Gb/5Gb ports Max Active 100Mb/1Gb SFP ports Max Active 1Gb/10Gb SFP+ ports* Max Active 25Gb SFP28 ports* Max Active 40Gb QSFP+ ports Max Active 50Gb ports Max Active 40Gb/ 50Gb Stacking ports*** Aggregated Switch Bandwidth Frame Forwarding Rate 5520-24T 24 0 0 12 12 2 4 2 648 Gbps 482.1 Mpps 5520-24W 24 0 0 12 12 2 4 2 648 Gbps 482.1 Mpps 5520-48T 48 0 0 12 12 2 4 2 696 Gbps 517.8 Mpps 5520-48W 48 0 0 12 12 2 4 2 696 Gbps 517.8 Mpps 5520-12MW-36W 36 12 0 12 12 2 4 2 792 Gbps 589.3 Mpps 5520-48SE 0 0 48 12 12 2 4 2 696 Gbps 517.8 Mpps 5520-24X 0 0 24 36 12 2 4 2 1080 Gbps 803.5 Mpps 5520-24T-ACDC 24 0 0 12 12 2 4 2 648 Gbps 482.1 Mpps 5520-48T-ACDC 48 0 0 12 12 2 4 2 696 Gbps 517.8 Mpps 5520-24X-ACDC 0 0 24 36 12 2 4 2 1080 Gbps 803.5 Mpps 5520-48SE-ACDC 0 0 48 12 12 2 4 2 696 Gbps 517.8 Mpps * Includes 8 ports available through channelization of the 2 x QSFP28 ports when not used for stacking with Switch Engine, or with VOSS 8.4.2 or later Available through channelization of the 2 x QSFP28 ports when these ports are not used for stacking in Switch Engine, or with VOSS 8.4.2 or later * 50Gb stacking with Switch Engine mode only 31.6 or later Software Scaling Values 5520 with Switch Engine
  • MAC Table: 114,688/65,536
  • IPv4 ARP Table: 60,000/41,000*
  • IPv4 Route Table: 81,000/16,000*
  • IP Multicast Entries (S,G,V): 43,000/24,000*
  • IPv6 ND Table: 18,000
  • IPv6 Route Table: 40,000/8,000*
  • ACL (Ingress/Egress): 9,216/1,024
  • QoS Egress Queues/Port: 8 www.extremenetworks.com 5
  • VLANs: 4,094
  • Routed VLANs: 2,048 * First value is the maximum; second is the default. Scaling limits are c onfigur able. See the Switch Engine Release Notes for additional details OnePolicy Scaling
  • Policy P r ofiles: 63
  • Unique permit/deny rules per switch: 8,120
  • Authenticated policy users/switch: 9,216 5520 with Fabric Engine
  • MAC Table: 40,960 (81,920 non-Fabric)
  • IPv4 ARP/IP Host Table: 16,000/48,000
  • IPv4 Route Table: 15,500
  • IP Multicast Routes: 4,000
  • IPv6 ND Table: 16,000
  • IPv6 Route Table: 7,500
  • IPv4 ACL (Ingress/Egress): 1,024/336
  • QoS Egress Queues/Port: 8
  • VLANs: 4,059
  • Routed VLANs: 500 Fabric Connect Scaling
  • Fabric Adjacencies per switch: 128
  • BEB Nodes per VSN: 500
  • L2 VSN: 3500
  • L3 VSN: 256 Weights and Dimensions Switches Switch Model Weight* Physical Dimensions Chassis Only With PSU Width: 441 mm (17.36 in.) Depth: 442 mm (17.42 in.) Height: 44 mm (1.73 in.) Width: 441 mm (17.36 in.) 5520-48T 5.76 kg (12.70 lb.) 5520-48W 6.06 kg (13.36 lb.) 5520-12MW-36W 6.33 kg (13.96 lb.) 5520-48SE 5.70 kg (12.57 lb.) 5520-24X 6.25 kg (13.78 lb.) Width: 431 mm (16.98 in.) Depth: 442 mm (17.42 in.) Not applicable 5520-48T-ACDC 5.95 kg (13.12 lb.) 5520-24X-ACDC 5.68 kg (12.52 lb.) 5520-48SE-ACDC 5.91 kg (13.03 lb.) * Switch weights include fans but no PSUs www.extremenetworks.com 6

Model Weight Physical Dimensions Width: 48.8 mm (1.92 in.) 5520-VIM-4YE 0.21 kg (0.46 lb.) Power Supplies Model Weight* Physical Dimensions Width: 40 mm (1.57 in.) 10941 (1100W AC) 1.16 kg (2.56 lb.) Width: 40 mm (1.57 in.) Depth: 292 mm (11.50 in.) Width: 73.7 mm (2.90 in.) XN-DCPWR-550W-FB 0.81 kg (1.79 lb.) XN-DCPWR-550W-BF 0.81 kg (1.79 lb.) Power Supply Unit Spec ifications 10953 10951 10941 XN-ACPWR-2000-F* Voltage Input Range (Nominal) 100VAC-127VAC/ 200VAC-240VAC 100VAC-127VAC/ 200VAC-240VAC 100VAC-127VAC/ 200VAC-240VAC 100VAC-127VAC/ 200VAC-240VAC Line Frequency Range 50Hz to 60Hz 50Hz to 60Hz 50Hz to 60Hz 50Hz to 60Hz Power Supply Input Socket IEC/EN 60320 C14 IEC/EN 60320 C16 IEC/EN 60320 C16 IEC/EN 60320 C16 Power Cord Input Plug IEC/EN 60320 C13 IEC/EN 60320 C15 IEC/EN 60320 C15 IEC/EN 60320 C15 Operating Temperature 0°C to 55°C (32°F to 131°F) Normal Operation 0°C to 50°C (32°F to 122°F) Normal Operation 0°C to 50°C (32°F to 122°F) Normal Operation 0°C to 55°C (32°F to 131°F) Normal Operation * 200VAC-240VAC is required to achieve full 2000W output. If run at 100VAC-120VAC, output is limited to 1100W. Power Supply Unit Spec ifications (cont.) XN-ACPWR-350W-FB XN-ACPWR-350W-BF XN-ACPWR-715W-FB XN-ACPWR-1100W-FB XN-ACPWR-2000W-FB* Voltage Input Range (Nominal) 100VAC-240VAC 100VAC-240VAC 100VAC-240VAC 100VAC-240VAC 100VAC-240VAC Line Frequency Range 50Hz to 60Hz 50Hz to 60Hz 50Hz to 60Hz 50Hz to 60Hz 50Hz to 60Hz www.extremenetworks.com 7

XN-ACPWR-350W-FB XN-ACPWR-350W-BF XN-ACPWR-715W-FB XN-ACPWR-1100W-FB XN-ACPWR-2000W-FB* Power Supply Input Socket IEC/EN 60320 C14 IEC/EN 60320 C14 IEC/EN 60320 C16 IEC/EN 60320 C16 IEC/EN 60320 C16 Power Cord Input Plug IEC/EN 60320 C13 IEC/EN 60320 C13 IEC/EN 60320 C15 IEC/EN 60320 C15 IEC/EN 60320 C15 Operating Temperature 0°C to 55°C (32°F to 131°F) Normal Operation 0°C to 55°C (32°F to 131°F) Normal Operation 0°C to 50°C (32°F to 122°F) Normal Operation 0°C to 50°C (32°F to 122°F) Normal Operation 0°C to 50°C (32°F to 122°F) Normal Operation * 200VAC-240VAC is required to achieve full 2000W output. If run at 100VAC-120VAC, output is limited to 1100W. Power Supply Unit Spec ifications (cont.) XN-ACPWR-550W-FB XN-ACPWR-550W-BF XN-DCPWR-550W-FB XN-DCPWR-550W-BF Voltage Input Range (Nominal) 100VAC-240VAC 100VAC-240VAC -48VDC (-36VDC to -72VDC) -48VDC (-36VDC to -72VDC) Line Frequency Range 50Hz to 60Hz 50Hz to 60Hz N/A N/A Power Supply Input Socket IEC 320 - C14 IEC 320 - C14 POSITRONIC PN# PLAH03M400A1/AA-E1A POSITRONIC PN# PLAH03M400A1/AA-E1A Power Cord Input Plug IEC 320 - C13 IEC 320 - C13 POSITRONIC PN# PLAH03M400A1/AA-E1A POSITRONIC PN# PLAH03M400A1/AA-E1A Operating Temperature 0°C to 50°C (32°F to 122°F) Normal Operation 0°C to 50°C (32°F to 122°F) Normal Operation 0°C to 50°C (32°F to 122°F) Normal Operation 0°C to 50°C (32°F to 122°F) Normal Operation PoE Power Budget Switch Model 1 x 715W 2x 715W 1 x 1100W 2 x 1100W 1 x 2000W @ 100-120VAC 1 x 2000W @ 200-240VAC 2 x 2000W @ 100-120VAC 2 x 2000W @ 200-240VAC 5520-24W 494W 1079W 879W 1781W 879W 1779W 1869W 2160W 5520-48W 483W 1068W 868W 1770W 868W 1768W 1858W 3568W 5520-12MW-36W 464W 1049W 849W 1751W 849W 1749W 1839W 3549W Note: It is recommended that primary and secondary power supply units (PSUs) be of the same type to support optimal PoE operation. Minimum/Maximum Power Consumption and Heat Dissipation Switch Model Minimum Power Consumption (W) Minimum Heat Dissipation (BTU/hr) Maximum Power Consumption (W)* Maximum Heat Dissipation (BTU/hr)** 5520-24T 52 176 142 483 5520-24W 54 182 2480 1092 www.extremenetworks.com 8

Switch Model Minimum Power Consumption (W) Minimum Heat Dissipation (BTU/hr) Maximum Power Consumption (W)* Maximum Heat Dissipation (BTU/hr)** 5520-48T 60 205 171 584 5520-48W 59 203 4100 1817 5520-12MW-36W 66 224 4095 1862 5520-48SE 61 209 255 872 5520-24X 48 165 171 585 5520-24T-ACDC 41 140 135 459 5520-48T-ACDC 46 156 141 481 5520-24X-ACDC 39 132 169 575 5520-48SE-ACDC 45 154 223 760 * Includes maximum PoE load (W) through the switch ** Does not include PoE load heat dissipated through external electronic load Fan and Acoustic Noise Switch Model Acoustic Information 5520-24T Typical: Single 350W AC PSU, no VIM Maximum: Dual 350W AC PSU, 5520-VIM-4YE Bystander Sound Pressure 39.6 dB(A),0˚C to 35˚C (32˚F to 95˚F) (Typical) 77.5 dB(A), 50˚C (122˚F) (Maximum) Sound Power

5.1 B, 0˚C to 35˚C (32˚F to 95˚F) (Typical)

8.46 B, 50˚C (122˚F) (Maximum)

5520-24W Typical: Single 715W AC PSU, no VIM Maximum: Dual 1100W AC PSU, 5520-VIM-4YE Bystander Sound Pressure 50.4 dB(A),0˚C to 35˚C (32˚F to 95˚F) (Typical) 67.1 dB(A), 25˚C (77˚F) (Maximum) 78.9 dB(A), 50˚C (122˚F) (Maximum) Sound Power

6 B, 0˚C to 35˚C (32˚F to 95˚F) (Typical)

7.61 B, 25˚C (77˚F) (Maximum)

8.6 B, 50˚C (122˚F) (Maximum)

5520-48T Typical: Single 350W AC PSU, no VIM Maximum: Dual 350W AC PSU, 5520-VIM-4YE Bystander Sound Pressure 39.0 dB(A),0˚C to 35˚C (32˚F to 95˚F) (Typical) 79.0 dB(A), 50˚C (122˚F) (Maximum) Sound Power

4.9 B, 0˚C to 35˚C (32˚F to 95˚F) (Typical)

8.52 B, 50˚C (122˚F) (Maximum)

5520-48W Typical: Single 1100W AC PSU, no VIM Maximum: Dual 2000W AC PSU (240VAC), 5520-VIM-4YE www.extremenetworks.com 9

Switch Model Acoustic Information Bystander Sound Pressure 64.3 dB(A),0˚C to 35˚C (32˚F to 95˚F) (Typical) 69.1 dB(A), 25˚C (77˚F) (Maximum) 79.4 dB(A), 50˚C (122˚F) (Maximum) Sound Power

7.24 B, 0˚C to 35˚C (32˚F to 95˚F) (Typical)

7.65 B, 25˚C (77˚F) (Maximum)

5520-12MW-36W Typical: Single 1100W AC PSU, no VIM Maximum: Dual 2000W AC PSU (240VAC), 5520-VIM-4YE Bystander Sound Pressure 62.7 dB(A),0˚C to 35˚C (32˚F to 95˚F) (Typical) 69.2 dB(A), 25˚C (77˚F) (Maximum) 78.8 dB(A), 50˚C (122˚F) (Maximum) Sound Power

7.25 B, 0˚C to 35˚C (32˚F to 95˚F) (Typical)

7.64 B, 25˚C (77˚F) (Maximum)

5520-48SE Typical: Single 350W AC PSU, no VIM Maximum: Dual 350W AC PSU, 5520-VIM-4YE Bystander Sound Pressure 41.4 dB(A),0˚C to 35˚C (32˚F to 95˚F) (Typical) 77.9 dB(A), 50˚C (122˚F) (Maximum) Sound Power

5.14 B, 0˚C to 35˚C (32˚F to 95˚F) (Typical)

8.53 B, 50˚C (122˚F) (Maximum)

5520-24X Typical: Single 350W AC PSU, no VIM Maximum: Dual 350W AC PSU, 5520-VIM-4YE Bystander Sound Pressure 40.6 dB(A),0˚C to 35˚C (32˚F to 95˚F) (Typical) 76.9 dB(A), 50˚C (122˚F) (Maximum) Sound Power

5.05 B, 0˚C to 35˚C (32˚F to 95˚F) (Typical)

5520-24T-ACDC Typical: F2B Air flo w ; Single 550W AC PSU, no VIM Maximum: F2B Air flo w ; Dual 550W AC PSU, with 5520-VIM-4YE Bystander Sound Pressure 38.6 dB(A), 0˚C to 40˚C (Typical) 76.5 dB(A), 50˚C (Maximum) Sound Power

4.94 B, 0˚C to 40˚C (Typical)

8.60 B, 50˚C (Maximum)

Typical: F2B Air flo w ; Single 550W DC PSU, no VIM Maximum: F2B Air flo w ; Dual 550W DC PSU, with 5520-VIM-4YE Bystander Sound Pressure 38.2 dB(A), 0˚C to 40˚C (Typical) 77.0 dB(A), 50˚C (Maximum) Sound Power

4.89 B, 0˚C to 40˚C (Typical)

8.56 B, 50˚C (Maximum)

Typical: B2F Air flo w ; Single 550W AC PSU, no VIM Maximum: B2F Air flo w ; Dual 550W AC PSU, with 5520-VIM-4YE Bystander Sound Pressure 38.46dB(A), 0˚C to 40˚C (Typical) 76.6 dB(A), 50˚C (Maximum) Sound Power

4.99 B, 0˚C to 40˚C (Typical)

8.61 B, 50˚C (Maximum)

Typical: B2F Air flo w ; Single 550W DC PSU, no VIM Maximum: B2F Air flo w ; Dual 550W DC PSU, with 5520-VIM-4YE Bystander Sound Pressure 39.8 dB(A), 0˚C to 40˚C (Typical) 79.0 dB(A), 50˚C (Maximum) Sound Power

5.03 B, 0˚C to 40˚C (Typical)

8.69 B, 50˚C (Maximum)

www.extremenetworks.com 10

Switch Model Acoustic Information 5520-48T-ACDC Typical:F2B Air flo w ; Single 550W AC PSU, no VIM Maximum: F2B Air flo w ; Dual 550W AC PSU, with 5520-VIM-4YE Bystander Sound Pressure 38.2 dB(A), 0˚C to 40˚C (Typical) 76.4 dB(A), 50˚C (Maximum) Sound Power

4.91 B, 0˚C to 40˚C (Typical)

8.58 B, 50˚C (Maximum)

Typical: F2B Air flo w ; Single 550W DC PSU, no VIM Maximum: F2B Air flo w ; Dual 550W DC PSU, with 5520-VIM-4YE Bystander Sound Pressure 38.1 dB(A), 0˚C to 40˚C (Typical) 77.1 dB(A), 50˚C (Maximum) Sound Power

4.88 B, 0˚C to 40˚C (Typical)

8.55 B, 50˚C (Maximum)

Typical: B2F Air flo w ; Single 550W AC PSU, no VIM Maximum: B2F Air flo w ; Dual 550W AC PSU, with 5520-VIM-4YE Bystander Sound Pressure 38.5 dB(A), 0˚C to 40˚C (Typical) 76.7 dB(A), 50˚C (Maximum) Sound Power

8.54 B, 50˚C (Maximum)

Typical: B2F Air flo w ; Single 550W DC PSU, no VIM Maximum: B2F Air flo w ; Dual 550W DC PSU, with 5520-VIM-4YE Bystander Sound Pressure 39.6 dB(A), 0˚C to 40˚C (Typical) 79.0 dB(A), 50˚C (Maximum) Sound Power

5.00 B, 0˚C to 40˚C (Typical)

8.70 B, 50˚C (Maximum)

5520-48SE-ACDC Typical: F2B Air flo w ; Single 550W AC PSU, no VIM Maximum: F2B Air flo w ; Dual 550W AC PSU, with 5520-VIM-4YE Bystander Sound Pressure 39.0 dB(A), 0˚C to 40˚C (Typical) 76.6 dB(A), 50˚C (Maximum) Sound Power

4.98 B, 0˚C to 40˚C (Typical)

8.65 B, 50˚C (Maximum)

Typical: F2B Air flo w ; Single 550W DC PSU, no VIM Maximum: F2B Air flo w ; Dual 550W DC PSU, with 5520-VIM-4YE Bystander Sound Pressure 38.7 dB(A), 0˚C to 40˚C (Typical) 77.2 dB(A), 50˚C (Maximum) Sound Power

4.96 B, 0˚C to 40˚C (Typical)

8.64 B, 50˚C (Maximum)

Typical: B2F Air flo w ; Single 550W AC PSU, no VIM Maximum: B2F Air flo w ; Dual 550W AC PSU, with 5520-VIM-4YE Bystander Sound Pressure 38.9 dB(A), 0˚C to 40˚C (Typical) 77.4 dB(A), 50˚C (Maximum) Sound Power

4.95 B, 0˚C to 40˚C (Typical)

Typical: B2F Air flo w ; Single 550W DC PSU, no VIM Maximum: B2F Air flo w ; Dual 550W DC PSU, with 5520-VIM-4YE Bystander Sound Pressure 40.2 dB(A), 0˚C to 40˚C (Typical) 79.5 dB(A), 50˚C (Maximum) Sound Power

5.04 B, 0˚C to 40˚C (Typical)

8.75 B, 50˚C (Maximum)

www.extremenetworks.com 11

Switch Model Acoustic Information 5520-24X-ACDC Typical: F2B Air flo w ; Single 550W AC PSU, no VIM Maximum: F2B Air flo w ; Dual 550W AC PSU, with 5520-VIM-4YE Bystander Sound Pressure 38.1 dB(A), 0˚C to 40˚C (Typical) 75.8 dB(A), 50˚C (Maximum) Sound Power

4.90 B, 0˚C to 40˚C (Typical)

8.59 B, 50˚C (Maximum)

Typical: F2B Air flo w ; Single 550W DC PSU, no VIM Maximum: F2B Air flo w ; Dual 550W DC PSU, with 5520-VIM-4YE Bystander Sound Pressure 38.0 dB(A), 0˚C to 40˚C (Typical) 76.6 dB(A), 50˚C (Maximum) Sound Power

8.53 B, 50˚C (Maximum)

Typical: B2F Air flo w ; Single 550W AC PSU, no VIM Maximum: B2F Air flo w ; Dual 550W AC PSU, with 5520-VIM-4YE Bystander Sound Pressure 38.3 dB(A), 0˚C to 40˚C (Typical) 77.3 dB(A), 50˚C (Maximum) Sound Power Typical: B2F Air flo w ; Single 550W DC PSU, no VIM Maximum: B2F Air flo w ; Dual 550W DC PSU, with 5520-VIM-4YE Bystander Sound Pressure 40.1 dB(A), 0˚C to 40˚C (Typical) 79.3 dB(A), 50˚C (Maximum) Sound Power

8.73 B, 50˚C (Maximum)

Environmental Spec ifications EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational EN/ETSI 300 753 (1997-10) - Acoustic Noise ASTM D3580 Random Vibration Unpackaged 1.5 G Environmental Compliance EU RoHS - 2011/65/EU EU WEEE - 2012/19/EU EU REACH - Regulation (EC) No 1907/2006 - Reporting China RoHS - SJ/T 11363-2006 Taiwan RoHS - CNS 15663 (2013.7) Environmental Operating Conditions Temp: 0°C to 50°C (32°F to 122°F) for Front-Back cooling Temp: 0°C to 45°C (32°F to 113°F) for Back-Front cooling (5520-24T, 5520-24x, 5520-48T, 5520-48SE) Humidity: 5% to 95% relative humidity, non-condensing Altitude: 0 to 3,000 meters (9,850 feet) Shock (half sine): 98m/s2 (10G), 11ms, 18 shocks Random vibration: 3Hz to 500Hz at 1.5 G rms Packaging and Storage Spec ifications Temp: -40°C to 70°C (-40°F to 158°F) Humidity: 5% to 95% relative humidity, non-condensing Packaged Shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks Packaged Vibration: 5Hz to 62Hz at velocity 5 mm/s, 62Hz to 500Hz at 0.2 G Packaged Random Vibration: 5Hz to 20Hz at 1.0 ASD w/–3 dB/oct. from 20Hz to 200Hz Packaged Drop Height: 14 drops minimum on sides and corners at 42 inches (<15 kg box) Regulatory and Safety North American ITE UL 60950-1 UL/CuL 62368-1 Listed Complies with FCC 21CFR 1040.10 (U.S. Laser Safety) CDRH Letter of Approval (US FDA Approval) CAN/CSA 22.2 No. 60950-1 European ITE EN 60950-1, EN 62368-1 EN 60825-1 Class 1 (Lasers Safety) 2014/35/EU Low Voltage Directive www.extremenetworks.com 12

CB Report and C er tificat e per IEC 60950-1 IEC 62368-1 EMI/EMC Standards North American EMC for ITE FCC CFR 47 Part 15 Class A (USA) CB Report and C er tificat e IEC 62368-1 RoHS Directive 2011/65/EU AS/NZS 60950-1 (Australia /New Zealand) European EMC Standards EN 55035 EN 55032 Class A EN 55024 EN 55011 EN 61000-3-2,2014 (Harmonics) EN 61000-3-3 2013 (Flicker) EN 300 386 (EMC Telecommunications) 2014/30/EU EMC Directive International EMC C er tifications CISPR 32, Class A (International Emissions) AS/NZS CISPR32 CISPR 24 Class A (International Immunity) IEC 61000-4-2/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15 kV Air, Criteria B IEC 61000-4-3 /EN 61000-4-3 Radiated Immunity 10V/m, Criteria A IEC 61000-4-4/EN 61000-4-4 Transient Burst, 1 kV, Criteria AB IEC 61000-4-5 /EN 61000-4-5 Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria B IEC 61000-4-6 Conducted Immunity, 0.15-80 MHz, 10V/m unmod. RMS, Criteria A IEC/EN 61000-4-11 Power Dips & Interruptions, >30%, 25 periods, Criteria C Country Spec ific VCCI Class A (Japan Emissions) ACMA RCM (Australia Emissions) CCC Mark (China) KCC Mark, EMC Approval (Korea) EAC Mark (Custom Union) NRCS Mark (South Africa) BSMI Mark (Taiwan) Anatel (Brazil) NoM (Mexico) IEEE 802.3 Media Access Standards IEEE 802.3ab 1000BASE-T IEEE 802.3bz 2.5G/5GBASE-T IEEE 802.3bt Type4 PoE IEEE 802.3ae 10GBASE-X IEEE 802.3aq 10GBASE-LRM IEEE 802.3by 25GBASE-X IEEE 802.3ba/802.3bm 40GBASE-X and 100GBASE-X IEEE 802.3az Energy Effic ient Ethernet Ordering Notes Customers ordering a 5520 Series switch receive the base switch along with Base software license, fan modules and rack-mount kit. At least one Power Supply Unit (PSU) is required for 5520 operation, and a second PSU is required for redundancy and/or additional power. Versatile Interface Modules (VIMs), power supplies, transceiver/ optics, power cords, as well as Premier and MACsec licenses must be ordered separately. Base Software and Optional Premier License The Base software included with each 5520 unit supports most available switch features. Certain features, however, require a Premier license to operate. For Switch Engine, a Premier License is required for:

  • 5 or more OSPF interfaces
  • PIM DM / PM SSM
  • Anycast RP (Rendezvous Point)
  • Multi-Source Discovery Protocol (MSDP)
  • IS-IS/BGP4/MBGP*
  • GRE Tunneling
  • EthernetVPN (EVPN)
  • Multi-Protocol Label Switching (MPLS)*** For Fabric Engine, a Premier License is required for:
  • 5 or more OSPF or RIP interfaces
  • 3 or more BGP peers
  • 25 or more VRFs**
  • Layer 3 Virtual Service Networks (L3 VSNs)
  • Distributed Virtual Routing (DvR) Controller * Up to 2 BGP interfaces included in Base software with the EXOS

31.4 Release

VRFs included in Base software with the VOSS 8.4 Release * MPLS available with Switch Engine 31.6 release www.extremenetworks.com 13

Ordering Information

5520 Systems - Fans Included

Part Number Product Name Product Description 5520-24T 5520 24-port Switch 5520 Universal Switch with 24 x 10/100/1000BASE-T Full / Half-Duplex MACsec-capable ports, includes 2 x Stacking/QSFP28 ports, 2 fan modules, 1 VIM slot, 2 unpopulated modular PSU slots, Base software license. 5520-24W 5520 24-port 90w PoE Switch 5520 Universal Switch with 24 x 10/100/1000BASE-T Full / Half-Duplex 802.3bt 90W PoE MACsec-capable ports, includes 2 x Stacking/QSFP28 ports, 3 fan modules, 1 VIM slot, 2 unpopulated modular PSU slots, Base software license. 5520-48T 5520 48-port Switch 5520 Universal Switch with 48 x 10/100/1000BASE-T Full / Half-Duplex MACsec-capable ports, includes 2 x Stacking/QSFP28 ports, 3 fan modules, 1 VIM slot, 2 unpopulated modular PSU slots, Base software license. 5520-48W 5520 48-port 90w PoE Switch 5520 Universal Switch with 48 x 10/100/1000BASE-T Full / Half-Duplex 802.3bt 90W PoE MACsec-capable ports, includes 2 x Stacking/QSFP28 ports, 3 fan modules, 1 VIM slot, 2 unpopulated modular PSU slots, Base software license. 5520-12MW-36W 5520 48-port 90w PoE with 12 ports multi-rate Switch 5520 Universal Switch with 12 x 100Mb/1Gb/2.5Gb/5Gb 802.3bt 90W PoE MACsec-capable ports plus 36 x 10/100/1000BASE-T 802.3bt 90W PoE Full / Half-Duplex MACsec-capable ports, includes 2 x Stacking/QSFP28 ports, 3 fan modules, 1 VIM slot, 2 unpopulated modular PSU slots, Base software license. 5520-24X 5520 24-port SFP+ Switch 5520 Universal Switch with 24 x 100Mb/1Gb/10Gb SFP+ ports, includes 2 Stacking/QSFP28 ports, 2 fan modules, 1 VIM slot, 2 unpopulated modular PSU slots, Base software license.

5520 Systems – Without Fans and PSUs (ordered separately)

Part Number Product Name Product Description 5520-24T-BASE 5520 24-port Switch 5520 Universal Switch with 24 x 10/100/1000BASE-T Full / Half-Duplex MACsec-capable ports, includes 2 x Stacking/QSFP28 ports, 2 unpopulated fan slots, 1 VIM slot, 2 unpopulated modular PSU slots, Base software license. 5520-48T-BASE 5520 48-port Switch 5520 Universal Switch with 48 x 10/100/1000BASE-T Full / Half-Duplex MACsec-capable ports, includes 2 x Stacking/QSFP28 ports, 3 unpopulated fan slots, 1 VIM slot, 2 unpopulated modular PSU slots, Base software license. 5520-48SE 5520 48-port SFP Switch 5520 Universal Switch with 48 x 100M/1Gb SFP MACsec-capable ports, includes 2 x Stacking/ QSFP28 ports, 3 unpopulated fan slots, 1 VIM slot, 2 unpopulated modular PSU slots, Base software license. 5520-48SE-BASE 5520 48-port SFP Switch 5520 Universal Switch with 48 x 100M/1Gb SFP MACsec-capable ports, includes 2 x Stacking/ QSFP28 ports, 3 unpopulated fan slots, 1 VIM slot, 2 unpopulated modular PSU slots, Base software license. 5520-24X-BASE 5520 24-port SFP+ Switch 5520 Universal Switch with 24 x 100Mb/1Gb/10Gb SFP+ ports, includes 2 Stacking/QSFP28 ports, 2 unpopulated fan slots, 1 VIM slot, 2 unpopulated modular PSU slots, Base software license. www.extremenetworks.com 14

5520 Systems - AC/DC Switches without Fans and PSUs (ordered separately)

Part Number Product Name Product Description 5520-24T-ACDC-BASE 5520 24-port Switch 5520 Universal Switch with 24 x 10/100/1000BASE-T FDX/HDX MACsec-capable ports, 2 x Stacking/QSFP28 ports, 1 unpopulated VIM slot, 3 unpopulated modular fan slots, 2 unpopulated modular PSU slots, AC or DC PSU capable. 5520-48T-ACDC-BASE 5520 48-port Switch 5520 Universal Switch with 48 x 10/100/1000BASE-T FDX/HDX MACsec-capable ports, 2 x Stacking/QSFP28 ports, 1 unpopulated VIM slot, 3 unpopulated modular fan slots, 2 unpopulated modular PSU slots, AC or DC PSU capable. 5520-24X-ACDC-BASE 5520 24-port SFP+ Switch 5520 Universal Switch with 24 x 1Gb/10Gb SFP+ ports, 2 Stacking/QSFP28 ports, 1 unpopulated VIM slot, 3 unpopulated modular fan slots, 2 unpopulated modular PSU slots, AC or DC PSU capable. 5520-48SE-ACDC-BASE 5520 48-port SFP Switch 5520 Universal Switch with 48 x 1000BASE-X SFP MACsec capable ports, 2 x Stacking/ QSFP28 ports, 1 unpopulated VIM slot, 3 unpopulated modular fan slots, 2 unpopulated modular PSU slots, AC or DC PSU capable. Versatile Interface Modules Part Number Product Name Product Description 5520-VIM-4X 4-port SFP+ module 5520 Versatile Interface Module with 4 x 1/10Gb SFP+ ports 5520-VIM-4XE 4-port SFP+ module LRM/ MACsec capable

5520 Versatile Interface Module with 4 x 1/10Gb SFP+ LRM and MACsec-capable ports

5520-VIM-4YE 4-port SFP28 module MACsec capable

5520 Versatile Interface Module with 4 x 10/25Gb SFP28 MACsec-capable ports

Power Supplies for use with 5520 AC only Part Number Product Name Product Description 10953 350W AC PSU FB 350W AC PSU supported on 5520 10951 715W AC PSU FB 715W AC PSU supported on 5520 10941 1100W AC PSU FB 1100W AC PSU supported on 5520 XN-ACPWR-2000W-F 2000W AC PSU FB 2000W AC PSU supported on 5520 XN-ACPWR-350W-FB* 350W AC PSU FB 350W AC Power Supply Module - Front to Back air flo w , also used on X465 and VSP 4900 XN-ACPWR-715W-FB* 715W AC PSU FB 715W AC PoE Power Supply Module - Front to Back air flo w , also used on 5720, X465, and VSP 4900 XN-ACPWR-1100W-FB* 1100W AC PSU FB 1100W AC PoE Power Supply Module - Front to Back air flo w , also used on 5720, X465, and VSP 4900 XN-ACPWR-2000W-FB* 2000WAC PSU FB 2000W AC PoE Power Supply Module - Front to Back air flo w , also used on 5720, X465, and VSP 4900 XN-ACPWR-350W-BF 350W AC PSU BF 350W Back to Front cooling AC PSU supported on 5520 Non-PoE switches * XN-ACPWR-xxx-FB power supply units cannot be used with the 10941, 10951, 10953, or XN-ACPWR-2000W-F PSUs on the same switch. Not available for Mexico, Russia, Brazil, China, Korea, South Africa, India at present, pending c er tification. www.extremenetworks.com 15

Power Supplies for use with 5520-ACDC Switches Part Number Product Name Product Description XN-ACPWR-550W-FB 550W AC PSU FB 550W AC Power Supply Module - Front to Back air flo w XN-ACPWR-550W-BF 550W AC PSU BF 550W AC Power Supply Module - Back to Front air flo w XN-DCPWR-550W-FB 550W DC PSU FB 550W DC Power Supply Module - Front to Back air flo w XN-DCPWR-550W-BF 550W DC PSU BF 550W DC Power Supply Module - Back to Front air flo w Fan Modules and Rack Mount Kits Part Number Product Name Product Description

17115 Spare Fan Module FB Fan module for 5520, Front to Back air flo w

17116 Spare Fan Module BF Fan module for 5520, Back to Front air flo w

XN-4P-RMKIT-005 4-Post Rack Mount Kit Spare 4-Post Rack Mount Kit for 5520 XN-2P-RMKIT-005 2-Post Rack Mount Kit Optional 2-Post Rack Mount Kit for 5520 The optional 2-post rack mount kit can be used with 5520 chassis HW rev AD or higher. Software Licenses Part Number Product Name Product Description 5000-PRMR-LIC-P Premier License for 5000 Series Perpetual Premier License for 5000 Series switches 5000-MACSEC-LIC-P MACsec License for the 5000 Series Perpetual MACsec license for the 5000 Series switches www.extremenetworks.com 16

All 5520 Series models are covered under Extreme’s Universal LLW policy. For warranty details, please visit our Policies and Warranties page. Power Cords Power cords are not included with the 5520 in support of our green initiatives but can be ordered separately. Optics / Transceivers For a list of the optics and transceivers supported on the 5520 Series hardware, refer to our Extreme Optics Compatibility Tool. Maintenance Services Extreme’s maintenance and support services are provided by 100% in- house engineering experts. We have a rate of over 90% fir st -per son resolution, ensuring effic ient operation of your business- essential network. With 24x7x365 phone support, advanced parts replacement, and on-site support, we augment your staff with expert resources to help you mitigate critical network issues fast. Visit ExtremeWorks Maintenance Services for more information. C er tifications For information on Industry, Security, and Government c er tifications for 5520 Series models, contact your Sales Representative. ©2024 Extreme Networks, Inc. All rights reserved. Extreme Networks and the Extreme Networks logo are trademarks or registered trademarks of Extreme Networks, Inc. in the United States and/or other countries. All other names are the property of their respective owners. For additional information on Extreme Networks Trademarks, see https://www.extremenetworks.com/about-extreme-networks/company/legal/trademarks. Spec ifications and product availability are subject to change without notice. 30oct24 www.extremenetworks.com 17