1071 ETC2

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(free datasheet download site)
  • PDF pages: 1

Technical content

Kanson Electronics, Inc. 800-233-9354 or 931-796-3050 Fax: 931-796-3956 www.issc-kanson.com INDUSTRIAL SOLID STATE TIMER MODEL 1071 PLUG IN ORDERING CODE 1071 - 2 - P - 1 - A BASIC MODEL NUMBER 1071 INPUT VOLTAGE 1 120VAC 2 24VAC/DC TIME RANGE (Secs) P (includes the following time ranges) 0 200-2000 4 0.75-7.5 1 50-500 5 0.2-2.0 2 12-120 6 0.06-.5 3 3-30 7 0.025-0.13 Consult factory for longer time ranges. TIMING FUNCTION

1 On delay

A* Relay SPDT w/ remote adjust (8 pin plug) B Relay DPDT (8 pin plug) C* Relay SPDT w/remote adjust (11 pin plug) *Units with remote adjust do not include a potentiometer in the timer. A separate 100kΩ potentiometer must be used with a maximum length of 12 feet of shielded twisted pair wire. APPLICABLE ACCESSORIES See accessory section for details Potentiometer RP-204 Reference dial RP-216 Locking attachment RP-217 8 pin socket RP-302 11 pin socket RP-303 Hold down clip RP-305 DIMENSIONS Inches (millimeters) On Delay Multi-Range unit is programmable for 8 different time ranges. The 1071 reduces inventory requirements by offering the time range capacity of eight separate timers in one unit. Input Power Actuates timing sequence, eliminating the need for a separate control circuit. Removing power automatically resets timing sequence. Input Is Compatible with both standard mechanical switches and solid state proximity sensors. ORDERING DATA VOLTAGE: 120VAC/DC, 24VAC/DC FREQUENCY: 50/60 Hz or DC TOLERANCE (VOLTAGE): ± 15% of nominal POWER CONSUMPTION: 4 VA maximum TRANSIENT PROTECTION: MOV SPECIFICATIONS INPUT TYPE: Electromechanical relay RATING: 5A @ 240VAC maximum TYPES: On delay REPEAT ACCURACY: ± 0.5 % of setting or 0.004 secs, whichever is greater. RESET TIME: 40 msec minimum INDICATION: LED - ON when timing TIMING RATIO: 10 to 1 potentiometer TIME RANGE: 8 per unit RANGE TOLERANCE: ±10% typical CONTROL: Power actuated or AC proximity sensor CONTROL TERMINALS: 2-7 (8 pin unit) 2-10 (11 pin unit) VOLTAGE PRESENT AT CONTROL TERMINALS: Same as input voltage OUTPUTTIMING OPERATING TEMP: -20° to 70° C (-4° to 158°F) TIMING VARIATION VS. TEMP: ± 5% maximum MOUNTING: Plug-in TERMINATION: 8 or 11 pin socket HOUSING: Plastic PHYSICAL WIRING OUTPUT A 2-7 Voltage input (control) 1-3 N.O. timed 1-4 N.C. timed 5-6 Remote adjust

8 Not used

Caution: Never apply voltage to 5-6 OUTPUT B 2-7 Voltage input (control) 1-3 N.O. timed 1-4 N.C. timed 8-6 N.O. timed 8-5 N.C. timed 5 4 3 7 8 1 2 OUTPUT C 2-10 Voltage input 11-8 N.C. timed (control) 5-6 Remote 1-3 N.O. timed adjust 1-4 N.C. timed 7 Not used 11-9 N.O. timed Caution: Never apply voltage to 5-6 8 7 6 5 4 9 10 1 2 311 Wiring Terminal Location switch positions 8 and 9 not used