1052434 PHOENIX

Document overview

  • Manufacturer or author: Provided By digicamel.com
  • PDF pages: 7

Technical content

https://www.phoenixcontact.com/us/products/1052434 12/24/2021 Page 1 / 7 I/O module - AXL F AI8 HART XC 1F - 1052434 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Axioline F XC, Analog input module, Active analog inputs: 8, 4 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors Product Description The module is an Axioline F I/O module for use in the Axioline F modular I/O system. The module is a modular I/O device that can be affixed to the Axioline F local bus, to communicate I/O data up to the Axioline F controller or bus coupler, which forms the head of the station. The analog input I/O module with HART capabilities collects analog input and HART data from the field I/O terminals and makes this information available to the controller / bus coupler through the Axioline F local bus. The active analog input module allows the connection of up to eight HART enabled, passive analog input signals. Your advantages Active analog input module Sources power for up to 8 HART enabled, passive analog input signals Cyclic access to PV, SV, TV, QV, and Loop Current Current range: 4 mA ... 20 mA Can be used under extreme ambient conditions Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet) Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626676265 Weight per Piece (excluding packing) 360.000 g Custom tariff number 85389091 Country of origin United States

https://www.phoenixcontact.com/us/products/1052434 12/24/2021 Page 2 / 7 I/O module - AXL F AI8 HART XC 1F - 1052434 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Use in potentially explosive areas is not permitted in China. Dimensions Width 53.6 mm Height 126.1 mm Depth 77.14 mm Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C (Standard) -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Maximum altitude 3000 m Degree of protection IP20 Connection data Designation Axioline F connector Connection method Push-in connection Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm General Mounting type DIN rail Color traffic grey A RAL 7042 Net weight 355 g

https://www.phoenixcontact.com/us/products/1052434 12/24/2021 Page 3 / 7 I/O module - AXL F AI8 HART XC 1F - 1052434 Technical data General Note on weight specifications with connectors and bus base module Mounting position any (no temperature derating) Maximum altitude 3000 m Interfaces Designation Axioline F local bus Number 2 Connection method Bus base module Transmission speed 100 Mbps Axioline potentials Designation Axioline F local bus supply (UBus) Supply voltage 5 V DC (via bus base module) Current consumption typ. 40 mA max. 60 mA Designation Supply for analog modules (UA) Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Current consumption max. 240 mA Analog inputs Description of the input HART enabled, passive analog input signals Input name Active analog inputs Number of inputs 8 (HART) Connection method Push-in connection Connection technology 2-conductor Note regarding the connection technology shielded, twisted pair Current input signal 4 mA ... 20 mA Precision 0.1 % (of measuring range final value for active mean-value generation and 30 Hz filter) Electrical isolation Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.

5 V supply of the local bus (UBus) / functional ground 500 V AC 50 Hz 1

min. 24 V supply (I/O) / functional ground 500 V AC 50 Hz 1 min. Field to functional earth 500 V AC 50 Hz 1 min. Field to 5V or 24V supplies 1500 V AC 50 Hz 1 min. Standards and Regulations

https://www.phoenixcontact.com/us/products/1052434 12/24/2021 Page 4 / 7 I/O module - AXL F AI8 HART XC 1F - 1052434 Technical data Standards and Regulations Immunity to ESD Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion A, 6 kV contact discharge, 8 kV air discharge Immunity to EF Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m Immunity to burst Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV Immunity to surge Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion A, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables Immunity to conducted interference Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V Interference emission Noise emission test in accordance with EN 61000-6-4/IEC 61000-6-4 Class A Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g ATEX DEMKO 20 ATEX 2334X II 3G Ex ec IIC T4 Gc IECEx IECEx UL 20.0002X Ex ec IIC T4 Gc UL, USA / Canada Class I, Div. 2, Groups A, B, C, D T4 Protection class III (IEC 61140, EN 61140, VDE 0140-1) Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 25; For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings

https://www.phoenixcontact.com/us/products/1052434 12/24/2021 Page 5 / 7 I/O module - AXL F AI8 HART XC 1F - 1052434 Dimensional drawing 53,6 77,1 122,4 126,1 Classifications eCl@ss eCl@ss 10.0.1 27242601 eCl@ss 11.0 27242601 eCl@ss 9.0 27242601 ETIM ETIM 7.0 EC001596 UNSPSC UNSPSC 18.0 32151602 UNSPSC 19.0 32151602 UNSPSC 20.0 32151602 UNSPSC 21.0 32151602 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals ATEX / IECEx / UL Listed / cUL Listed / cULus Listed Approval details

https://www.phoenixcontact.com/us/products/1052434 12/24/2021 Page 6 / 7 I/O module - AXL F AI8 HART XC 1F - 1052434 Approvals UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cULus Listed Accessories Accessories Device marking Insert label - EMT (35X46)R - 0801604 Insert label, for the Axioline F series from Phoenix Contact, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, THERMOMARK ROLL X1, THERMOMARK ROLL 2.0, THERMOMARK ROLL, mounting type: snapped, lettering field size: 35 x 46 mm, Number of individual labels: 500 DIN rail connector Bus connector - AXL F BS F - 2688129 Axioline F bus base module for housing type F Shield connection

https://www.phoenixcontact.com/us/products/1052434 12/24/2021 Page 7 / 7 I/O module - AXL F AI8 HART XC 1F - 1052434 Accessories Shield connection - AXL SHIELD SET - 2700518 Axioline shield connection set (contains 2 shield bus holders and 2 SK 5 shield connection clamps) Terminal marking Zack marker strip - ZB 20,3 AXL UNPRINTED - 0829579 Zack marker strip for Axioline F (device labeling), in 2 x 20.3 mm pitch, unprinted, 25-section, for individual labeling with B-STIFT 0.8, X-PEN, or CMS-P1-PLOTTER Zack Marker strip, flat - ZBF 10/5,8 AXL UNPRINTED - 0829580 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snapped, for terminal block width: 10.15 mm, lettering field size: 4 of 10.15 x 5 mm and 1 of 5.8 x 5 mm, Number of individual labels: 50 Phoenix Contact 2021 © - all rights reserved http://www.phoenixcontact.com