0SPF001.TXCN LITTELFUSE
Document overview
- Manufacturer or author: Provided By digicamel.com
- PDF pages: 7
Technical content
Littelfuse.com/SPF_CN ©2025 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 01/08/2026 POWR-GARD® Fuse Datasheet SPF_CN Series Solar Fuses
1000 V dc • 1–30 A
Description
The SPF_CN Solar Protection Fuse series has been specifically designed for the protection of photovoltaic (PV) systems. This family of midget-style fuses (10 x 38 mm) can safely protect PV modules and conductors from reverse- overcurrent conditions. As PV systems have grown in size, so have the corresponding voltage requirements. This increase in system voltage has typically been intended to minimize power loss associated with long conductor runs. Standard circuit protection devices are not designed to completely protect photovoltaic panels. However, the SPF_CN series is UL Listed to safely interrupt faulted circuits up to this demanding voltage level. Littelfuse offers multiple ampere ratings to match specific requirements in a variety of applications. Features/Benefits Full range, fast-acting fuse helps eliminate common low-overload faults Prevents power generation losses due to nuisance tripping from changes in temperature PCB mount and dead-front holder options available
Applications
Battery charge controllers Recommended Accessories Fuse Holder: LPHV 1000 V dc POWR-Safe series Fuse Clips: 125004/125005 Web Resources Download technical documents: Littelfuse.com/Solar Specifications Voltage Rating 1000 V dc Amperage Rating 1, 2, 3, 3.5, 4, 5, 6, 8, 10, 12, 15, 20, 25, 30 Max. Interrupting Rating 20 kA: 1 A–20 A 50 kA: 25 A–30 A Time Constant ≤ 2 ms Material Body: melamine Caps: copper alloy Approvals UL listed US-CA (File: E339112) TUV (Cert: J 50494849) Applicable Standards UL 248-1, 248-19 IEC 60269-6 Environmental RoHS Compliant REACH Country of Origin China Part Numbering System 0SPF xxxx H XCN Package Quantity Series Amp Code T = 10 Fuses (ferrule style only) H = 100 Fuses Look for this logo to indicate products that are used in solar applications. Visit our website Littelfuse.com/solar for the latest updates on approvals, certifications, and new products. Options REACH Refer to Ampere Code column in Ordering Information table XCN = Ferrule XRCN = PCB XRTCN = Extended PCB
Littelfuse.com/SPF_CN ©2025 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 01/08/2026 POWR-GARD® Fuse Datasheet SPF_CN Series Solar Fuses
Ordering Information
SERIES AMPERAGE AMPERE CODE CATALOG NUMBER PRODUCT MARKING PACKING QUANTITY ORDERING PART NUMBER UPC CODE SPF 1 001. SPF001CN SPF 1A-CN 10 0SPF001.TXCN 07945826521 100 0SPF001.HXCN 07945826535 SPF 2 002. SPF002CN SPF 2A-CN 10 0SPF002.TXCN 07945826522 100 0SPF002.HXCN 07945826536 SPF 3 003. SPF003CN SPF 3A-CN 10 0SPF003.TXCN 07945826523 100 0SPF003.HXCN 07945826537 SPF 3.5 03.5 SPF03.5CN SPF 3-1/2A-CN 10 0SPF03.5TXCN 07945826524 100 0SPF03.5HXCN 07945826538 SPF 4 004. SPF004CN SPF 4A-CN 10 0SPF004.TXCN 07945826525 100 0SPF004.HXCN 07945826539 SPF 5 005. SPF005CN SPF 5A-CN 10 0SPF005.TXCN 07945826526 100 0SPF005.HXCN 07945826540 SPF 6 006. SPF006CN SPF 6A-CN 10 0SPF006.TXCN 07945826527 100 0SPF006.HXCN 07945826541 SPF 8 008. SPF008CN SPF 8A-CN 10 0SPF008.TXCN 07945826528 100 0SPF008.HXCN 07945826542 SPF 10 010. SPF010CN SPF 10A-CN 10 0SPF010.TXCN 07945826529 100 0SPF010.HXCN 07945826543 SPF 12 012. SPF012CN SPF 12A-CN 10 0SPF012.TXCN 07945826530 100 0SPF012.HXCN 07945826544 SPF 15 015. SPF015CN SPF 15A-CN 10 0SPF015.TXCN 07945826531 100 0SPF015.HXCN 07945826545 SPF 20 020. SPF020CN SPF 20A-CN 10 0SPF020.TXCN 07945826532 100 0SPF020.HXCN 07945826546 SPF 25 025. SPF025CN SPF 25A-CN 10 0SPF025.TXCN 07945826533 07945826547100 0SPF025.HXCN SPF 30 030. SPF030CN SPF 30A-CN 10 0SPF030.TXCN 07945826534 100 0SPF030.HXCN 07945826548 Ferrule Version Ferrule Version PCB Version Extended PCB Version Dimensions Inches (Millimeters) CHICAGO, ILLINOIS 60631 3RD ANGLE PROJECTION A OL-0SPF000.HXRTCN Littelfuse ® REVISION DRWG NO. TITLE B DRW DATE GRAMS/PIECE FINISH GOOD WT myork 4/13/2023 MATL SPEC FINISH UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994 DENOTES CRITICAL CHARACTERISTICS. DENOTES CPK DIMENSIONS, -MINIMUM CPK VALUE DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT AND TRACKING TO BE DEFINED IN LITTELFUSE INSPECTION INSTRUCTIONS. DENOTES CP DIMENSIONS, -MINIMUM CP VALUE MUST BE WITHIN THE DIMENSIONAL LIMITATIONS SHOWN ON DRAWING AND INITIALLY LOCATED TO ALLOW FOR MAXIMUM TOOL LIFE. CPK CP SHEET 1 OF 1 SCALE SPF WITH EXTENDED PCB LEADS NTS CRITICAL CHARACTERISTIC FOR PART SAFETY/COMPLIANCE<S> MOUNTING HOLE DETAIL REVISION REV DATE DESCRIPTION A 6/14/23 526562GCP - RELEASE MRY BILL OF MATERIAL NO COMPONENT NO DESCRIPTION QTY/M U/M 39.88 [1.570] MAX 37.84 [1.490] MIN 1.02 0.25 0.040 0.010[ ] 3.56 [0.140] REF 37.84 [1.490] MIN 39.88 [1.570] MAX 0.29 [0.012] REF 12.70 [0.500] 4.50 [0.177] 3.05 [0.120] 7.11 [0.280] 10.3 [0.406] CHICAGO, ILLINOIS 60631 3RD ANGLE PROJECTION A OL-0SPF000.HXRTCN Littelfuse ® REVISION DRWG NO. TITLE B DRW DATE GRAMS/PIECE FINISH GOOD WT myork 4/13/2023 MATL SPEC FINISH UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994 DENOTES CRITICAL CHARACTERISTICS. DENOTES CPK DIMENSIONS, -MINIMUM CPK VALUE DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT AND TRACKING TO BE DEFINED IN LITTELFUSE INSPECTION INSTRUCTIONS. DENOTES CP DIMENSIONS, -MINIMUM CP VALUE MUST BE WITHIN THE DIMENSIONAL LIMITATIONS SHOWN ON DRAWING AND INITIALLY LOCATED TO ALLOW FOR MAXIMUM TOOL LIFE. CPK CP SHEET 1 OF 1 SCALE SPF WITH EXTENDED PCB LEADS NTS CRITICAL CHARACTERISTIC FOR PART SAFETY/COMPLIANCE<S> MOUNTING HOLE DETAIL REVISION REV DATE DESCRIPTION A 6/14/23 526562GCP - RELEASE MRY BILL OF MATERIAL NO COMPONENT NO DESCRIPTION QTY/M U/M 39.88 [1.570] MAX 37.84 [1.490] MIN 1.02 0.25 0.040 0.010[ ] 3.56 [0.140] REF 37.84 [1.490] MIN 39.88 [1.570] MAX 0.29 [0.012] REF 12.70 [0.500] 4.50 [0.177] 3.05 [0.120] 7.11 [0.280] 10.3 [0.406]
0.06 REF
(1.524)
0.140 REF
(3.56) 0.012 REF(0.292)
1.570 MAX
(39.88)
1.490 MIN
(37.84) 1.570 (39.88) MAX 1.490 (37.84) MIN 0.040 ±0.001 (1.02 ±.025 )
0.50 REF
(12.70) 0.12 ±0.005 (3.05 ±0.13 ) 0.12 ±0.005 (3.05 ±0.13 ) MOUNTING H OLE DETAIL 0.28 ±0.005 (7.11 ±0.13 ) 1.5 (38.1) .406 (10.31) .378 (9.60) ±.031 (±.79) 0.406 ±0.004 (10.31 ±0.10 ) (1.524) (3.56) 0.012 REF(0.292) (39.88) (37.84) 1.570 (39.88) MAX 1.490 (37.84) MIN 0.040 ±0.001 (1.02 ±.025 ) (12.70) 0.12 ±0.005 (3.05 ±0.13 ) 0.12 ±0.005 (3.05 ±0.13 ) MOUNTING H OLE DETAIL 0.28 ±0.005 (7.11 ±0.13 ) 1.5 (38.1) .406 (10.31) .378 (9.60) ±.031 (±.79) 0.406 ±0.004 (10.31 ±0.10 ) (1.524) (3.56) 0.012 REF(0.292) (39.88) (37.84) 1.570 (39.88) MAX 1.490 (37.84) MIN 0.040 ±0.001 (1.02 ±.025 ) (12.70) 0.12 ±0.005 (3.05 ±0.13 ) 0.12 ±0.005 (3.05 ±0.13 ) MOUNTING H OLE DETAIL 0.28 ±0.005 (7.11 ±0.13 ) 1.5 (38.1) .406 (10.31) .378 (9.60) ±.031 (±.79) 0.406 ±0.004 (10.31 ±0.10 ) MOUNTING HOLE DETAILMOUNTING HOLE DETAIL CHICAGO, ILLINOIS 60631 3RD ANGLE PROJECTION A OL-0SPF000.HXRTCN Littelfuse ® REVISION DRWG NO. TITLE B DRW DATE GRAMS/PIECE FINISH GOOD WT myork 4/13/2023 MATL SPEC FINISH UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994 DENOTES CRITICAL CHARACTERISTICS. DENOTES CPK DIMENSIONS, -MINIMUM CPK VALUE DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT AND TRACKING TO BE DEFINED IN LITTELFUSE INSPECTION INSTRUCTIONS. DENOTES CP DIMENSIONS, -MINIMUM CP VALUE MUST BE WITHIN THE DIMENSIONAL LIMITATIONS SHOWN ON DRAWING AND INITIALLY LOCATED TO ALLOW FOR MAXIMUM TOOL LIFE. CPK CP SHEET 1 OF 1 SCALE SPF WITH EXTENDED PCB LEADS NTS CRITICAL CHARACTERISTIC FOR PART SAFETY/COMPLIANCE<S> MOUNTING HOLE DETAIL REVISION REV DATE DESCRIPTION A 6/14/23 526562GCP - RELEASE MRY BILL OF MATERIAL NO COMPONENT NO DESCRIPTION QTY/M U/M 39.88 [1.570] MAX 37.84 [1.490] MIN 1.02 0.25 0.040 0.010[ ] 3.56 [0.140] REF 37.84 [1.490] MIN 39.88 [1.570] MAX 0.29 [0.012] REF 12.70 [0.500] 4.50 [0.177] 3.05 [0.120] 7.11 [0.280] 10.3 [0.406]
Littelfuse.com/SPF_CN ©2025 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 01/08/2026 POWR-GARD® Fuse Datasheet SPF_CN Series Solar Fuses SERIES AMPERAGE AMPERE CODE CATALOG NUMBER PRODUCT MARKING PACKING QUANTITY ORDERING PART NUMBER UPC CODE SPF 1 001. SPF001RCN SPF 1A-RCN 100 0SPF001.HXRCN 07945827736 SPF 2 002. SPF002RCN SPF 2A-RCN 100 0SPF002.HXRCN 07945827737 SPF 3 003. SPF003RCN SPF 3A-RCN 100 0SPF003.HXRCN 07945827738 SPF 3 003. SPF003RTCN SPF 3A-RTCN 100 0SPF003.HXRTCN 07945865983 SPF 4 004. SPF004RCN SPF 4A-RCN 100 0SPF004.HXRCN 07945827740 SPF 5 005. SPF005RCN SPF 5A-RCN 100 0SPF005.HXRCN 07945827741 SPF 6 006. SPF006RCN SPF 6A-RCN 100 0SPF006.HXRCN 07945827742 SPF 8 008. SPF008RCN SPF 8A-RCN 100 0SPF008.HXRCN 07945827743 SPF 10 010. SPF010RCN SPF 10A-RCN 100 0SPF010.HXRCN 07945827744 SPF 12 012. SPF012RCN SPF 12A-RCN 100 0SPF012.HXRCN 07945827745 SPF 15 015. SPF015RCN SPF 15A-RCN 100 0SPF015.HXRCN 07945827746 SPF 20 020. SPF020RCN SPF 20A-RCN 100 0SPF020.HXRCN 07945827747 SPF 25 025. SPF025RCN SPF 25A-RCN 100 0SPF025.HXRCN 07945827748 SPF 30 030. SPF030RCN SPF 30A-RCN 100 0SPF030.HXRCN 07945827749 SPF 30 030. SPF030RTCN SPF 30A-RTCN 100 0SPF030.HXRTCN 07945831409 Electrical Specifications AMPERAGE AMPERE CODE CATALOG NUMBER (FERRULE) CATALOG NUMBER (PCB) CATALOG NUMBER (EXTENDED PCB) VOLTAGE INTERRUPTING RATING (kA) NOM COLD RESISTANCE (ohm) WATTS LOSS AT 100 % RATED CURRENT (W) WATTS LOSS AT 80 % RATED CURRENT (W) TOTAL CLEARING I2t (A2 s) 20 kA TOTAL CLEARING I2t (A2 s) 50 kA AGENCY APPROVALS DC DC UL TUV 4 004. SPF004CN SPF004RCN – 1000 20 0.061 1.49 0.84 23 – • • 5 005. SPF005CN SPF005RCN – 1000 20 0.041 1.47 0.86 43 – • • 6 006. SPF006CN SPF006RCN – 1000 20 0.028 1.35 0.77 80 – • • 8 008. SPF008CN SPF008RCN – 1000 20 0.018 1.61 0.91 199 – • • 10 010. SPF010CN SPF010RCN – 1000 20 0.013 1.76 1.00 401 – • • 12 012. SPF012CN SPF012RCN – 1000 20 0.010 1.97 1.11 642 – • • 15 015. SPF015CN SPF015RCN – 1000 20 0.008 2.28 1.38 505 – • • 20 020. SPF020CN SPF020RCN – 1000 20 0.005 2.81 1.57 1313 – • • 25 025. SPF025CN SPF025RCN – 1000 50 0.004 3.33 1.88 2141 2433 • • 30 030. SPF030CN SPF030RCN SPF030RTCN 1000 50 0.003 3.85 2.15 3290 3810 • • PCB and Extended PCB Versions
Littelfuse.com/SPF_CN ©2025 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 01/08/2026 POWR-GARD® Fuse Datasheet SPF_CN Series Solar Fuses AMPERAGE RATING OPENING TIME (MINUTES) 100 % of Amperage Rating per UL 113 % of Amperage Rating per IEC 135 % of Amperage Rating per UL 145 % of Amperage Rating per IEC 200 % of Amperage Rating per UL 1–30 Temperature Stabilization 60 Min 60 Max 60 Max 4 Max Electrical Specification – Agency Requirements -60°C -40°C -20°C 0°C 20°C 40°C 60°C 80°C 100°C 120°C 140°C -76°F -40°F -4°F 32°F 68°F 104°F 140°F 176°F 212°F 248°F 284°F AMBIENT TEMPERATURE PERCENT OF UPRATING PERCENT OF DOWNRATING T emperature Derating Curve (temperature of air immediately surrounding fuse) WAVE PARAMETER LEAD-FREE RECOMMENDATION Preheat: (Typical industry recommendation) Temperature minimum 130 ˚C Temperature maximum — Pre-heat time 75 seconds maximum Solder pot temperature 280 ˚C maximum Solder dwell time 270 ˚C for 8 seconds maximum Complete cycle time 250 seconds maximum Recommended Process Parameters CELSIUS 0 50 100 150 200 250 300 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 SECONDS Soldering Parameters
Littelfuse.com/SPF_CN ©2025 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 01/08/2026 POWR-GARD® Fuse Datasheet SPF_CN Series Solar Fuses - THIS DATA GENERATED IN EXCEL - 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 PROSPECTIVE R.M.S CURRENT IN AMPERES MELTING (PRE-ARCING) TIME IN SECONDS - 1A - 2A - 3A - 6A - 8A - 10A - 12A - 4A - 5A - 3.5A BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA
2 OF 4
E Time Current Curve (1–12 A)
Littelfuse.com/SPF_CN ©2025 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 01/08/2026 POWR-GARD® Fuse Datasheet SPF_CN Series Solar Fuses 1000900800700 600 500 400 1000900800700 600 500 400 1000900800 700 600 500 400 300 200 1009080 1098 1 0.90.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 300 200 100908070 300 200 100908070 5050 10987 10987 - 15A TIME IN SECONDS - 20A 10.90.80.7 0.6 0.5 0.4 0.3 0.2 10.90.80.7 0.6 0.5 0.4 0.3 0.2 0.10.090.080.07 0.06 0.05 0.04 0.03 0 02 0.10.090.080.07 0.06 0.05 0.04 0.03 0 020.02 0.01 0.02 0.01 1000900800 700 600 500 400 300 200 1009080 1098 10.90.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 CURRENT IN AMPERES TEST VOLTAGE: 1000V TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: BASIS FOR DATA: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 3/15/10 E
3 OF 4
- THIS DATA GENERATED IN EXCEL - Time Current Curve (15–20 A)
Littelfuse.com/SPF_CN ©2025 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 01/08/2026 POWR-GARD® Fuse Datasheet SPF_CN Series Solar Fuses Disclaimer Notice – Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for Time Current Curve (25–30 A) 1000900800700 600 500 400 1000900800700 600 500 400 1000900800 700 600 500 400 300 200 1009080 1098 1 0.90.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 300 200 100908070 300 200 100908070 5050 10987 109877 TIME IN SECONDS - 25A - 30A 10.90.80.7 0.6 0.5 0.4 0.3 0.2 10.90.80.7 0.6 0.5 0.4 0.3 0.2 0.10.090.080.07 0.06 0.05 0.04 0.03 0 02 0.10.090.080.07 0.06 0.05 0.04 0.03 0 020.02 0.01 0.02 0.01 1000900800 700 600 500 400 300 200 1009080 1098 10.90.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 CURRENT IN AMPERES TEST VOLTAGE: 1000V TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: BASIS FOR DATA: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 3/15/10 E
4 OF 4
- THIS DATA GENERATED IN EXCEL -